Micrel, Inc.
SY10/100EP451L
May 2007
6
M9999-051807-B
hbwhelp@micrel.com or (408) 955-1690
PECL 100EP DC Electrical Characteristics(8)
VCC = 3.3V; VEE = 0V; TA = –40°C to +85°C, unless otherwise stated.
(9)
-40°C
25°C
85°C
Symbol
Parameter
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
Units
IEE
Power Supply Current
85
120
85
120
85
120
mA
VOH
Output HIGH Voltage
(10)
2155
2280
2405
2155
2280
2405
2155
2280
2405
mV
VOL
Output LOW Voltage
(10)
1355
1480
1605
1355
1480
1605
1355
1480
1605
mV
VIH
Input HIGH Voltage (Single-Ended)
2075
2420
2075
2420
2075
2420
mV
VIL
Input LOW Voltage (Single-Ended)
1355
1675
1355
1675
1355
1675
mV
VIHCMR
Input HIGH Voltage Common Mode
Range (Differential Configuration)
(11)
2.0
3.3
2.0
3.3
2.0
3.3
V
IIH
Input HIGH Current
150
A
IIL
Input LOW Current
0.5
A
NECL 100EP DC Electrical Characteristics(8)
VCC = 0V; VEE = –3.0V to –3.6V; TA = –40°C to +85°C, unless otherwise stated.
-40°C
25°C
85°C
Symbol
Parameter
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
Units
IEE
Power Supply Current
85
120
85
120
85
120
mA
VOH
Output HIGH Voltage
(10)
-1145
-1020
-895
-1145
-1020
-895
-1145
-1020
-895
mV
VOL
Output LOW Voltage
(10)
-1945
-1820
-1695
-1945
-1820
-1695
-1945
-1820
-1695
mV
VIH
Input HIGH Voltage (Single-Ended)
-1225
-880
-1225
-880
-1225
-880
mV
VIL
Input LOW Voltage (Single-Ended)
-1945
-1625
-1945
-1625
-1945
-1625
mV
VIHCMR
Input HIGH Voltage Common Mode
Range (Differential Configuration)
(11)
VEE +2.0
0.0
VEE +2.0
0.0
VEE +2.0
0.0
V
IIH
Input HIGH Current
150
A
IIL
Input LOW Current
0.5
A
Notes:
8. The device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit board with
maintained transverse airflow greater than 500lfpm. Electrical parameters are guaranteed only over the declared operating temperature range.
Functional operation of the device exceeding these conditions is not implied. Device specifications limit values are applied individually under normal
operating conditions and not valid simultaneously.
9. Input and output parameters vary 1:1 with VCC.
10. All loading with 50 to VCC–2.0V.
11. VIHCMR (min) varies 1:1 with VEE, VIHCMR (max) varies 1:1 with VCC. The VIHCMR range is referenced to the most positive side of the differential input
signal.