S V G-2066 500MHz-2200MHz 6-Bit V GA
Caution: ESD Sensitive
Appropriate precaution in handling, packaging
and testing devices must be observed.
Absolute Maximum Ratings
Parameters
MIn
Max
Unit
VCC Bias Current (I
C
)
VCC Bias Voltage
220
mA
8
V
Power Dissipation
1.5
W
Drain Voltage (V
DD
)
Voltage on any Digital Input
-0.3
4.0
V
-0.3
VDD+0.3
V
Operating Lead Temperature (T
L
)
Max RF Input Power
-40
+85
oC
21
dBm
Storage Temperature Range
-40
+150
oC
Operating Junction Temperature (T
J
)
ESD Human Body Model
+150
oC
500
V
Operation of this device beyond any one of these limits may cause perma-
nent damage. For reliable continuous operation the device voltage and
current must not exceed the maximum operating values specified in the
table on page one.
Bias conditions should also satisfy the following expression:
I
D
V
D
< (T
J
- T
L
) / R
TH’
j-l
Specification continued
Parameters: Test Conditions
Z
0
= 50
, V
CC
= 5.0V,Vdd=3V Iq = 115mA
ERR
Atten setting accuracy any state (500MHz-2200MHz)
Symbol
Unit
Min.
Typ.
Max.
dB
+/- 0.2
+/- (0.2+3% Atten setting)
DYNR
Attenuation dynamic range
dB
30.3
31.5
32.7
FCLK
Serial Data Clock Frequency
MHz
20
VDD
Drain voltage of Attenuator
V
2.7
3.0
3.3
IDD
Drain Supply Current
uA
40
100
LH
Digital Logic High
V
0.7xVDD
VDD
LL
Digital Logic Low
V
0
0.3xVDD
ILEAK
Digital Logic Leakage
uA
1
Serial or Parallel Mode Selection
The SVG-2066 can be controlled with either a serial or parallel interface. The S-P bit selects the mode: S-P=low for parallel mode
and S-P=high for serial mode.
Parallel Mode Operation
For latched parallel interfacing the LE line should be held low while changing attenuation state control logic P0.5 thru P16. To load
data pulse LE from low to high and to low again. See Figure 1 and Table 1 on the next page for the parallel mode timing diagram
and specifications. For direct parallel mode operation the LE line should be held high and the attenuation state is directly loaded
when the parallel line logic changes. The truth table for parallel operation is shown in Table 2.
Serial Mode Operation
Three CMOS compatible signals control the attenuator in this mode: DATA, CLK and LE. When LE is high the latch is enabled and
data in the serial shift register gets loaded. When the LE is low the data in the shift register is latched. Refer to Figure 2 for the tim-
ing diagram and Table 3 for the timing specifications.
Power up State Programming
At power up in serial mode the six control bits are set to the values available on the six parallel inputs P0.5 thru P16 (see Table 2).
For parallel mode the power up state is set with the two bit word defined by U1 and U2. See the truth table in Table 4.
Digital Interfacing: