370A
INVERTER GRADE THYRISTORS
Hockey Puk Version
ST183C..C SERIES
1
Bulletin I25178 rev. B 04/00
www.irf.com
Typical Applications
Inverters
Choppers
Induction heating
All types of force-commutated converters
Features
Metal case with ceramic insulator
International standard case TO-200AB (A-PUK)
All diffused design
Center amplifying gate
Guaranteed high dV/dt
Guaranteed high dI/dt
High surge current capability
Low thermal impedance
High speed performance
case style TO-200AB (A-PUK)
I
T(AV)
370
A
@ T
hs
55
°C
I
T(RMS)
690
A
@ T
hs
25
°C
I
TSM
@ 50Hz
4900
A
@ 60Hz
5130
A
I2t@ 50Hz
120
KA2s
@ 60Hz
110
KA2s
V
DRM
/V
RRM
400 to 800
V
t
q
range
10 to 20
s
T
J
- 40 to 125
°
C
Parameters
ST183C..C
Units
Major Ratings and Characteristics