57
HOW TO ORDER
Military Type Designation:
Established Reliability = CCR05, CCR06, CCR07, CCR08, CCR09
Non-Established Reliability = CC05, CC06, CC07, CC08, CC09
MIL-C-20/Radial Leads
MIL Part No. Codes
Style:
CC
= Identifies temperature compensating,
ceramic dielectric, fixed capacitors.
R
= Identifies Established Reliability parts.
06
= Numbers identify shape and dimension.
Temperature Characteristic:
1/ Not practically measurable.
2/ The ppm/°C values for -55°C were calculated by dividing ppm by
negative 80°C.
Capacitance Code:
First two digits are the significant figures of capacitance.
Third digit indicates the additional number of zeros. For
example, order 18,000 pF as 183. (For values below 10
pF, use “R” in place of decimal point, e.g., 1R4 = 1.4pF).
Capacitance Tolerance:
C = ±0.25 pF, D = ±0.5 pF, F = ±1%, G = ±2%,
J = ±5%, K = ±10%
Military Failure Rate:
M = 1% per 1000 hours, P = 0.1% per 1000 hours,
R = 0.01% per 1000 hours, S = 0.001% per 1000 hours.
PACKAGING REQUIREMENTS
Packaging:
CCR0X: 100 pcs/bag; CC0X: 1000 pcs/bag
Permissible capacitance change from capacitance at +25°C in ppm/°C
Temp.
Characteristic
CJ
CX
CK
CH
CG
+125°C
1/
±250 ppm/°C ±120 ppm/°C
+246.25
-326.25
±60 ppm/°C
+55.00
-91.25
±30 ppm/°C
+27.50
-53.75
-55°C 2/
1/
+116.25
-166.25
SIZE SPECIFICATIONS
Per MIL
Spec
Dimensions: Millimeters (Inches)
Case Size
Lead
Spacing
(L.S.)
5.08±.38
Lead
Diameter
(L.D.)
.64±.05
MIL-C-20
Length
(L)
4.83±.25
(.190±.010) (.190±.010)
7.37±.25
(.290±.010) (.290±.010)
12.19±.51
(.480±.020) (.480±.020)
12.19±.51
(.480±.020) (.480±.020)
4.83±.25
(.190±.010) (.190±.010)
Width
(W)
4.83±.25
Thickness
(T)
2.29±.25
2.29±.25
5.08±.38
(.090±.010) (.200±.015) (.025±.002)
3.56±.25
10.16±.51
(.140±.010) (.400±.020) (.025±.002)
6.1±.25
10.16±.51
(.240±.010) (.400±.020) (.025±.002)
2.29±.25
2.54±.38
(.090±.010) (.100±.015) (.025±.002)
CCR05/CC05
Figures 1, 4
CCR06/CC06
Figures 2, 3
CCR07/CC07
Figure 2
CCR08/CC08
Figure 2
CCR09/CC09
Figure 2
7.37±.25
.64±.05
12.19±.51
.64±.05
12.19±.51
.64±.05
4.83±.25
.64±.05
L.D.
L.D.
L.D.
L.D.
L.S.
L.S.
L.S.
L.S.
W
W
W
W
T
T
T
L
L
L
L
1.250 Min.
1.250 Min.
Figure 1
Figure 2
Figure 4
Figure 3
Military Type
Designation
Capacitance
(pF)
Capacitance
Tolerance
WVDC
CC05-CCR05, CC09-CCR09
CCR05CX1R0_
CCR05CX1R1_
CCR05CX1R2_
CCR05CX1R3_
CCR05CX1R5_
CCR05CX1R6_
CCR05CX1R8_
CCR05CX2R0_
CCR05CK2R2_
CCR05CK2R4_
CCR05CK2R7_
CCR05CK3R0_
CCR05CK3R3_
CCR05CK3R6_
CCR05CK3R9_
1.0
1.1
1.2
1.3
1.5
1.6
1.8
2.0
2.2
2.4
2.7
3.0
3.3
3.6
3.9
C
C
C
C
C
C
C
C
C
C
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
C, D
C, D
C, D
C, D
C, D
Military Type
Designation
Capacitance
(pF)
Capacitance
Tolerance
WVDC
CC05-CCR05, CC09-CCR09
CCR05CJ4R3_
CCR05CJ4R7_
CCR05CJ5R1_
CCR05CJ5R6_
CCR05CJ6R2_
CCR05CJ6R8_
CCR05CJ7R5_
CCR05CH8R2_
CCR05CH9R1_
CCR05CH100_
CCR05CH110_
CCR05CH120_
CCR05CH130_
CCR05CH150_
CCR05CH160_
4.3
4.7
5.1
5.6
6.2
6.8
7.5
8.2
9.1
10
11
12
13
15
16
C, D
C, D
C, D
C, D
C, D
C, D
C, D
C, D
C, D
G, J
G, J
G, J
G, J
G, J
G, J
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
Add appropriate failure rate level (M, P, R, or S), add V for Stand-off
Add appropriate cap. tolerance letter
Add appropriate failure rate level (M, P, R, or S), add V for Stand-off
Add appropriate cap. tolerance letter
Part Number Example
Style
CCR06
CG
183
J
R
(V)
Temperature Characteristic
Capacitance Code
Capacitance Tolerance
Military Failure Rate
Stand-off Option
To order stand-off option, place “V” at the end of the part number.
For example: CCR05CG332FSV.
MILITARY PART NUMBER IDENTIFICATION