SN74CBT16233
16-BIT 1-OF-2 FET MULTIPLEXER/DEMULTIPLEXER
SCDS010K
–
MAY 1995
–
REVISED NOVEMBER 2001
2
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
FUNCTION TABLE
(each multiplexer/demultiplexer)
INPUTS
SEL
L
FUNCTION
TEST
L
A = B1
H
L
A = B2
X
H
A = B1 and A = B2
logic diagram (positive logic)
8B1
1B1
8A
1A
SEL1
1B2
8B2
TEST1
1
45
30
27
56
55
11
12
16B1
9B1
16A
9A
SEL2
9B2
16B2
TEST2
15
31
29
28
42
41
25
26
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
Input voltage range, V
I
(see Note 1)
Continuous channel current
Input clamp current, I
IK
(V
I
< 0)
Package thermal impedance,
θ
JA
(see Note 2): DGG package
–
0.5 V to 7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–
0.5 V to V
CC
+ 0.5 V
128 mA
–
50 mA
64
°
C/W
48
°
C/W
56
°
C/W
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DGV package
DL package
Storage temperature range, T
stg
Stresses beyond those listed under
“
absolute maximum ratings
”
may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under
“
recommended operating conditions
”
is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
2. The package thermal impedance is calculated in accordance with JESD 51-7.
–
65
°
C to 150
°