SN55114, SN75114
DUAL DIFFERENTIAL LINE DRIVERS
SLLS071C – SEPTEMBER 1973 – REVISED SEPTEMBER 1998
3
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC
(see Note 1)
Input voltage, V
I
Off-state voltage applied to open-collector outputs
Continuous total power dissipation
Storage temperature range, T
stg
Case temperature for 60 seconds, T
c
: FK package
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: J or W package
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: D or N package
7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.5 V
12 V
See Dissipation Rating Table
–65
°
C to 150
°
C
260
°
C
300
°
C
260
°
C
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltage values are with respect to the network ground terminal.
DISSIPATION RATING TABLE
PACKAGE
TA
≤
25
°
C
POWER RATING
DERATING FACTOR
ABOVE TA = 25
°
C
7.6 mW/
°
C
11.0 mW/
°
C
11.0 mW/
°
C
9.2 mW/
°
C
8.0 mW/
°
C
TA = 70
°
C
POWER RATING
TA = 125
°
C
POWER RATING
D
950 mW
608 mW
—
FK
J
1375 mW
880 mW
275 mW
1375 mW
880 mW
275 mW
N
1150 mW
736 mW
—
W
1000 mW
640 mW
200 mW
In the FK, J, and W packages, SN55114 chips are either silver glass or alloy mounted.
recommended operating conditions (unless otherwise noted)
SN55114
NOM
SN75114
NOM
UNIT
MIN
MAX
MIN
MAX
Supply voltage, VCC
High-level input voltage, VIH
Low-level input voltage, VIL
High-level output current, IOH
Low-level output current, IOL
Operating free-air temperature, TA
4.5
5
5.5
4.75
5
5.25
V
2
2
V
0.8
0.8
V
–40
–40
mA
40
40
mA
°
C
–55
125
0
70