PECL DC CHARACTERISTICS
(1) (V
CC = 5 V; VEE = 0 V)
(2)
NECL DC CHARACTERISTICS
(1) (V
CC = 0 V; VEE = 5 V)
(2)
www.ti.com............................................................................................................................................................................................ SLLS920 – DECEMBER 2008
–40°C
25°C
85°C
PARAMETER
UNIT
MIN
TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX
ICC
Power-supply current
18
26
21
26
23
26
mA
VOH
Output HIGH voltage(3)
3915
4120
3915
4000
4120
3915
4120
mV
VOL
Output LOW voltage(3)
3170
3380
3170
3288
3380
3170
3380
mV
VIH
Input HIGH voltage (single-ended)
3835
4120
3835
4120
3835
4120
mV
VIL
Input LOW voltage (single-ended)
3190
3525
3190
3525
3190
3525
mV
Input HIGH voltage, common-mode
VIHCMR
2.5
4.6
2.5
4.6
2.5
4.6
V
range (differential)(4)
IIH
Input HIGH current
150
A
IIL
Input LOW current
0.5
A
(1)
The device meets these specifications after thermal equilibrium has been established when mounted in a test socket or printed-circuit
board with maintained transverse airflow greater than 500 lfpm (2.54 m/s). Electrical parameters are assured only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
(2)
Input and output parameters vary 1:1 with VCC. VEE can vary +0.25 V / –0.5 V.
(3)
Outputs are terminated through a 50-
resistor to VCC – 2 V.
(4)
VIHCMR min varies 1:1 with VEE; VIHCMR max varies 1:1 with VCC. The VIHCMR range is referenced to the more-positive side of the
differential input signal. Normal operation is obtained if the HIGH level falls within the specified range and the peak-to-peak voltage lies
between VPP min and 1 V.
PARAMETER
–40°C
25°C
85°C
UNIT
MIN
TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX
IEE
Power-supply current
19
26
21
26
23
26
mA
VOH
Output HIGH voltage(3)
–1085
–880
–1025
–995
–880
–1025
–880
mV
VOL
Output LOW voltage(3)
–1830
–1620
–1810
–1712
–1620
–1810
–1620
mV
VIH
Input HIGH voltage (single-ended)
–1165
–880
–1165
–880
–1165
–880
mV
VIL
Input LOW voltage (single-ended)
–1810
–1475
–1810
–1475
–1810
–1475
mV
Input HIGH voltage, common-mode
VIHCMR
–2.5
–0.4
–2.5
–0.4
–2.5
–0.4
V
range (differential)(4)
IIH
Input HIGH current
150
A
IIL
Input LOW current
0.5
A
(1)
The device meets these specifications after thermal equilibrium has been established when mounted in a test socket or printed-circuit
board with maintained transverse airflow greater than 500 lfpm (2.54 m/s). Electrical parameters are assured only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
(2)
Input and output parameters vary 1:1 with VCC. VEE can vary +0.25 V / –0.5 V.
(3)
Outputs are terminated through a 50-
resistor to VCC – 2 V.
(4)
VIHCMR min varies 1:1 with VEE; VIHCMR max varies 1:1 with VCC. The VIHCMR range is referenced to the more-positive side of the
differential input signal. Normal operation is obtained if the HIGH level falls within the specified range and the peak-to-peak voltage lies
between VPP min and 1 V.
Copyright 2008, Texas Instruments Incorporated
3