SN55LBC173
QUADRUPLE LOW-POWER DIFFERENTIAL RECEIVER
SGLS081 – MARCH 1995
3
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
schematics of inputs and outputs
TYPICAL OF ALL OUTPUTS
VCC
Y Output
EQUIVALENT OF A AND B INPUTS
12 k
3 k
18 k
1 k
VCC
100 k
A Only
Input
100 k
B Only
Input
VCC
Receiver
TYPICAL OF G AND G INPUTS
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
(see Note 1)
Input voltage, V
I
(A or B inputs)
Differential input voltage, V
ID
(see Note 2)
Data and control voltage range
Continuous total dissipation
Operating free-air temperature range, T
A
Storage temperature range, T
stg
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds
–0.3 V to 7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
±
25 V
±
25 V
–0.3 V to 7 V
See Dissipation Rating Table
–55
°
C to 125
°
C
–65
°
C to 150
°
C
260
°
C
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltage values are with respect to GND.
2. Differential input voltage is measured at the noninverting input with respect to the corresponding inverting input.
DISSIPATION RATING TABLE
PACKAGE
TA
≤
25
°
C
POWER RATING
DERATING FACTOR
ABOVE TA = 25
°
C
11.0 mW/
°
C
11.0 mW/
°
C
8.0 mW/
°
C
TA = 125
°
C
POWER RATING
FK
1375 mW
275 mW
J
1375 mW
275 mW
W
1000 mW
200 mW
recommended operating conditions
MIN
NOM
MAX
UNIT
Supply voltage, VCC
Common-mode input voltage, VIC
Differential input voltage, VID
High-level input voltage, VIH
Low-level input voltage, VIL
High-level output current, IOH
Low-level output current, IOL
Operating free-air temperature, TA
4.75
5
5.25
V
–7
12
±
6
V
V
G inputs
2
V
0.8
V
–8
mA
16
mA
°
C
–55
125