SN55ALS161, SN75ALS161
OCTAL GENERAL-PURPOSE INTERFACE BUS TRANSCEIVERS
SLLS019E – JUNE 1986 – REVISED NOVEMBER 1999
5
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC
(see Note 1)
Input voltage, V
I
Low-level driver output current, I
OL
Continuous total dissipation
Package thermal impedance,
θ
JA
(see Note 2): DW package
7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.5 V
100 mA
See Dissipation Rating Table
58
°
C/W
69
°
C/W
260
°
C
300
°
C
260
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
N package
Case temperature for 60 seconds: FK package, T
C
Lead temperature 1,6 mm (1/16 inch) from the case for 60 seconds: J or W package
Lead temperature 1,6 mm (1/16 inch) from the case for 10 seconds: DW or N package
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltage values are with respect to network ground terminal.
2. The package thermal impedance is calculated in accordance with JESD 51.
. . . . . . . . . . . . .
. . . . . . . . . . .
–65
°
C to 150
°
C
DISSIPATION RATING TABLE
PACKAGE
TA
≤
25
°
C
POWER RATING
OPERATING
FACTOR
TA = 70
°
C
POWER RATING
TA = 125
°
C
POWER RATING
FK
1375 mW
11.0 mW/
°
C
11.0 mW/
°
C
8.0 mW/
°
C
880 mW
275 mW
J
1375 mW
880 mW
275 mW
W
1000 mW
640 mW
200 mW
SN55ALS161 recommended operating conditions
MIN
NOM
MAX
UNIT
Supply voltage, VCC
4.75
5
5.25
V
TE and DC at TA = –55
°
C to 125
°
C
Bus and terminal at TA = 25
°
C to 125
°
C
Bus and terminal at TA = –55
°
C
TE and DC at TA = –55
°
C to 125
°
C
Bus and terminal at TA = 25
°
C to –55
°
C
Bus and terminal at TA = 125
°
C
Bus ports with pullups active (VCC = 5 V)
Terminal ports
2
High-level input voltage, VIH
2
V
2.1
0.8
Low-level input voltage, VIL
0.8
V
0.7
High level output current IOH
High-level output current, IOH
–5.2
mA
μ
A
–800
Low level output current IOL
Low-level output current, IOL
Bus ports
48
mA
Terminal ports
16
Operating free-air temperature, TA
–55
125
°
C