MC1488, SN55188, SN75188
QUADRUPLE LINE DRIVERS
SLLS094B – SEPTEMBER 1983 – REVISED MAY 1995
3
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature (unless otherwise noted)
Supply voltage, V
CC+
at (or below) 25
°
C free-air temperature (see Notes 1 and 2)
Supply voltage, V
CC–
at (or below) 25
°
C free-air temperature (see Notes 1 and 2)
Input voltage, V
I
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage, V
O
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total power dissipation (see Note 2)
Operating free-air temperature range, T
A
: SN55188
MC1488, SN75188
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Case temperature for 60 seconds, FK package
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: D or N package
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: J or W package
15 V
–15 V
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
–15 V to 7 V
–15 V to 15 V
See Dissipation Rating Table
–55
°
C to 125
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
0
°
C to 70
°
C
–65
°
C to 150
°
C
260
°
C
260
°
C
300
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltage values are with respect to the network ground terminal.
2. For operation above 25
°
C free-air temperature, refer to the maximum supply voltage curve, Figure 6. In the FK and J packages,
SN55188 chips are alloy mounted.
DISSIPATION RATING TABLE
PACKAGE
TA
≤
25
°
C
POWER RATING
DERATING FACTOR
ABOVE TA = 25
°
C
7.6 mW/
°
C
11.0 mW/
°
C
11.0 mW/
°
C
9.2 mW/
°
C
TA = 70
°
C
POWER RATING
TA = 125
°
C
POWER RATING
D
950 mW
608 mW
–
FK
1375 mW
880 mW
275 mW
J
1375 mW
880 mW
275 mW
N
1150 mW
736 mW
–
W
1000 mW
8.0 mW/
°
C
640 mW
200 mW
recommended operating conditions
SN55188
NOM
MC1488, SN75188
MIN
NOM
UNIT
MIN
MAX
MAX
Supply voltage, VCC+
Supply voltage, VCC–
High-level input voltage, VIH
Low-level input voltage, VIL
Operating free-air temperature, TA
7.5
9
15
7.5
9
15
V
–7.5
–9
–15
–7.5
–9
–15
V
1.9
1.9
V
0.8
0.8
V
°
C
–55
125
0
70