SN55114, SN75114
DUAL DIFFERENTIAL LINE DRIVERS
SLLS071C – SEPTEMBER 1973 – REVISED SEPTEMBER 1998
4
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
SN55114
TYP
SN75114
TYP
UNIT
MIN
MAX
MIN
MAX
VIK
Input clamp voltage
VCC = MIN,
VCC = MIN,
VIL = 0.8 V
II = –12 mA
VIH = 2 V,
–0.9
–1.5
–0.9
–1.5
V
VOH
High-level output
voltage
IOH = –10 mA
IOH = – 40 mA
2.4
3.4
2.4
3.4
V
2
3
2
3
VOL
Low-level output
voltage
VCC = MIN,
VIL = 0.8 V,
VCC = 5 V,
VCC = MAX,
VIH = 2 V,
IOL = 40 mA
IO = 40 mA,
IO = –40 mA,
0 2
0.2
0 4
0.4
0 2
0.2
0 45
0.45
V
VOK
Output clamp voltage
TA = 25
°
C
TA = 25
°
C
TA = 25
°
C
TA = 125
°
C
TA = 25
°
C
TA = 70
°
C
6.1
6.5
6.1
6.5
V
–1.1
–1.5
–1.1
–1.5
VOH= 12 V
VOH = 12 V
1
100
IO( ff)
IO(off)
Off-state open collector
output current
VCC= MAX
VCC = MAX
200
μ
A
VOH= 5 25 V
VOH = 5.25 V
1
100
200
II
Input current at
maximum input voltage
VCC= MAX
VCC = MAX,
VI= 5 5 V
VI = 5.5 V
1
1
mA
IIH
IIL
High-level input current
VCC = MAX,
VCC = MAX,
VI = 2.4 V
VI = 0.4 V
40
40
μ
A
mA
Low-level input current
–1.1
–1.6
–1.1
–1.6
IOS
Short-circuit
output current§
VCC= MAX
VCC = MAX,
VO= 0
VO = 0,
TA= 25
TA = 25
°
C
–120
–120
mA
–40
–90
–40
–90
ICC
Supply current
(both drivers)
All inputs at 0 V, No load,
TA = 25
°
C
VCC = MAX
VCC = 7 V
37
47
50
65
37
47
50
70
mA
All parameters, with the exception of off-state open-collector output current, are measured with the active pullup connected to the sink output.
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
All typical values are at TA = 25
°
C and VCC = 5 V, with the exception of ICC at 7 V.
§Only one output should be shorted at a time, and duration of the short circuit should not exceed one second.
switching characteristics, V
CC
= 5 V, T
A
= 25
°
C
PARAMETER
TEST
SN55114
TYP
SN75114
TYP
UNIT
CONDITIONS
MIN
MAX
MIN
MAX
tPLH
tPHL
Propagation delay time, low- to high-level output
Propagation delay time, high- to low-level output
CL = 30 pF,
See Figure 1
15
11
20
20
15
11
30
30
ns
ns