SN55107A, SN75107A, SN75107B, SN75108A
DUAL LINE RECEIVERS
SLLS069D – JANUARY 1977 – REVISED APRIL 1998
4
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature (unless otherwise noted)
Supply voltage, V
CC+
(see Note 3)
Supply voltage, V
CC–
Differential input voltage, V
ID
(see Note 4)
Common-mode input voltage, V
IC
(see Note 5)
Strobe input voltage
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total dissipation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Case temperature for 60 seconds, T
c
: FK package
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: J package
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: D, N, or W package
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
3. All voltage values, except differential voltages, are with respect to network ground terminal.
4. Differential voltage values are at the noninverting (A) terminal with respect to the inverting (B) terminal.
5. Common-mode input voltage is the average of the voltages at the A and B inputs.
7 V
–7 V
±
6 V
±
5 V
5.5 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
See Dissipation Rating Table
–65
°
C to 150
°
C
260
°
C
300
°
C
260
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . .
DISSIPATION RATING TABLE
PACKAGE
TA
≤
25
°
C
POWER RATING
DERATING FACTOR
ABOVE TA = 25
°
C
7.6 mW/
°
C
11.0 mW/
°
C
11.0 mW/
°
C
9.2 mW/
°
C
8.0 mW/
°
C
TA = 70
°
C
POWER RATING
TA = 125
°
C
POWER RATING
D
950 mW
608 mW
—
FK
1375 mW
880 mW
275 mW
J
1375 mW
880 mW
275 mW
N
1150 mW
736 mW
—
W
1000 mW
640 mW
200 mW
recommended operating conditions (see Note 6)
SN55107A
SN75107A, SN75107B,
SN75108A
UNIT
MIN
NOM
MAX
MIN
NOM
MAX
Supply voltage, VCC+
Supply voltage, VCC–
High-level input voltage between differential inputs, VIDH (see Note 7)
Low-level input voltage between differential inputs, VIDL (see Note 7)
Common-mode input voltage, VIC (see Notes 7 and 8)
Input voltage, any differential input to GND (see Note 8)
4.5
5
5.5
4.75
5
5.25
V
–4.5
–5
–5.5
–4.75
–5
–5.25
V
0.025
–5
–3
–5
5
0.025
–5
–3
–5
5
V
–0.025
–0.025
V
3
3
V
3
3
V
High-level input voltage at strobe inputs, VIH(S)
Low-level input voltage at strobe inputs, VIL(S)
Low-level output current, IOL
Operating free-air temperature, TA
The algebraic convention, in which the less positive (more negative) limit is designated as minimum, is used in this data sheet for input voltage
levels only.
NOTES:
6. When using only one channel of the line receiver, the strobe input (G) of the unused channel should be grounded and at least one
of the differential inputs of the unused receiver should be terminated at some voltage between –3 V and 3 V.
7. The recommended combinations of input voltages fall within the shaded area in Figure 1.
8. The common-mode voltage may be as low as –4 V provided that the more positive of the two inputs is not more negative than
–3 V.
2
5.5
2
5.5
V
0
0.8
0
0.8
V
–16
–16
mA
°
C
–55
125
0
70