absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
Input voltage range:Control inputs (see Note 1)
I/O ports (see Note 1)
Voltage range applied to any output in the disabled or power-off state, V
O
Voltage range applied to any output in the high state, V
O
Input clamp current
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Current into any output in the low state: SN54BCT544
SN74BCT544
Operating free-air temperature range:
SN54BCT544
SN74BCT544
Storage temperature range
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
– 0.5 V to 7 V
– 0.5 V to 7 V
– 0.5 V to 5.5 V
– 0.5 V to 7 V
– 0.5 V to V
CC
–30 mA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
96 mA
128 mA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
– 55
°
C to 125
°
C
0
°
C to 70
°
C
– 65
°
C to 150
°
C
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input negative voltage rating may be exceeded if the input clamp-current rating is observed.
recommended operating conditions
SN54BCT544
MIN
NOM
SN74BCT544
MIN
NOM
UNIT
MAX
MAX
VCC
VIH
VIL
IIK
IOH
IOL
TA
Supply voltage
4.5
5
5.5
4.5
5
5.5
V
High-level input voltage
2
2
V
Low-level input voltage
0.8
0.8
V
Input clamp current
–18
–18
mA
High-level output current
–12
–15
mA
Low-level output current
48
64
mA
°
C
Operating free-air temperature
–55
125
0
70