SN54AHC27, SN74AHC27
TRIPLE 3-INPUT POSITIVE-NOR GATES
SCLS363 – MAY 1997
2
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
logic diagram, each gate (positive logic)
A
B
C
Y
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
Input voltage range, V
I
(see Note 1)
Output voltage range, V
O
(see Note 1)
Input clamp current, I
IK
(V
I
< 0)
Output clamp current, I
OK
(V
O
< 0 or V
O
> V
CC
)
Continuous output current, I
O
(V
O
= 0 to V
CC
)
Continuous current through V
CC
or GND
Package thermal impedance,
θ
JA
(see Note 2): D package
–0.5 V to 7 V
–0.5 V to 7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DB package
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
N package
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PW package
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The package thermal impedance is calculated in accordance with JESD 51, except for through-hole packages, which use a trace
length of zero.
–0.5 V to V
CC
+ 0.5 V
–20 mA
±
20 mA
±
25 mA
±
50 mA
127
°
C/W
158
°
C/W
78
°
C/W
170
°
C/W
–65
°
C to 150
°
C
recommended operating conditions (see Note 3)
SN54AHC27
MIN
SN74AHC27
MIN
UNIT
MAX
MAX
VCC
Supply voltage
2
5.5
2
5.5
V
VIH
Hi h l
High-level input voltage
VCC = 2 V
VCC = 3 V
VCC = 5.5 V
VCC = 2 V
VCC = 3 V
VCC = 5.5 V
1.5
1.5
V
2.1
2.1
3.85
3.85
VIL
Low-level input voltage
0.5
0.5
V
0.9
0.9
1.65
1.65
VI
VO
Input voltage
0
5.5
0
5.5
V
Output voltage
0
VCC
–50
0
VCC
–50
V
IOH
Hi h l
High-level output current
VCC = 2 V
VCC = 3.3 V
±
0.3 V
VCC = 5 V
±
0.5 V
VCC = 2 V
VCC = 3.3 V
±
0.3 V
VCC = 5 V
±
0.5 V
VCC = 3.3 V
±
0.3 V
VCC = 5 V
±
0.5 V
A
–4
–4
mA
–8
–8
IOL
Low-level output current
50
50
A
4
4
mA
8
8
t
v
/
Input transition rise or fall rate
100
100
ns/V
20
20
TA
Operating free-air temperature
–55
125
–40
85
°
C
NOTE 3: Unused inputs must be held high or low to prevent them from floating.
P