111
Parameter
Output Voltage
Dropout Voltage
Line Regulation
Load Regulation
Temperature Coefficient
of Output Voltage
Quiescent Circuit
Current*
3
Quiescent Circuit
Current (Output OFF)*
3
Overcurrent Protection
Starting Current*
1
Control Voltage (Output ON)
Control Voltage (Output OFF)
V
C
Control Current
Terminal
*2
(Output ON)
Control Current
(Output OFF)
OCP Detection Voltage Level
Delay Threshold Voltage
Delay Terminal Output Current
Before OCP
Flag
Output
Detection
Terminal
After OCP
Detection
G
SLA3005M/3006M/3007M
*1 I
S1
is specified at –5(%) drop point of output voltage V
O
on the condition that V
IN
= 7V, I
O
= 0.1A.
*2 Output is ON even when output control terminal V
C
is open. Each input level is equivalent to LS-TTL. Therefore, it may be directly driven by an
LS-TTL circuit.
*3 Total of four circuits
*
The FLG output latched by delay DLY after OCP detection. (SLA3005M/SLA3007M (ch1 to 3) shuts down the output voltage simultaneously at
latching.) Set the V
IN
or V
C
to low to reset latching. Leave a time lag of C
d
×
600s or more before restart.
**
SLA3007Mch4 does not have the FLG output function.
Unit
V
V
mV
mV
mV/
°
C
mA
mA
A
V
μ
A
μ
A
V
V
μ
A
V
V
I
Electrical Characteristics
SLA3005M
min.
typ.
max.
4.85
5.00
5.15
V
IN
=7V, I
O
=0.1A
0.5
I
O
≤
0.5A
30
V
IN
=6 to 15V, I
O
=0.1A
50
V
IN
=7V, I
O
=0 to 0.5A
±
0.5
V
IN
=7V, I
O
=5mA, T
j
=–10 to 100
°
C
20
V
IN
=7V, I
O
=0A
0.5
V
IN
=7V, V
C
1 to 4=0V
0.55
0.65
V
IN
=7V
2.0
0.7
50
V
C
=2.7V
–100
V
C
=0V
4.0
3.7
4.3
2.1
2.3
2.5
35
50
65
V
IN
–0.4
R
FLG
connected between FLG and V
IN
0.5
I
FLG
=1mA
SLA3006M
min.
typ.
max.
4.85
5.00
5.15
V
IN
=7V, I
O
=0.1A
0.5
I
O
≤
0.5A
30
V
IN
=6 to 15V, I
O
=0.1A
50
V
IN
=7V, I
O
=0 to 0.5A
±
0.5
V
IN
=7V, I
O
=5mA, T
j
=–10 to 100
°
C
20
V
IN
=7V, I
O
=0A
0.5
V
IN
=7V, V
C
1 to 4=0V
0.75
0.96
V
IN
=7V
2.0
0.7
50
V
C
=2.7V
–100
V
C
=0V
4.0
3.7
4.3
2.1
2.3
2.5
35
50
65
V
IN
–0.4
R
FLG
connected between FLG and V
IN
0.5
I
FLG
=1mA
(T
a
=25
°
C unless otherwise specified)
Ratings
SYmbol
V
O
Conditions
V
DIF
Conditions
V
OLINE
Conditions
V
OLOAD
Conditions
V
O
/
T
a
Conditions
I
q
Conditions
I
q(off)
Conditions
I
S1
Conditions
V
C.
IH
V
C.
IL
I
C.
IH
Conditions
I
C.
IL
Conditions
V
oth
V
DLYth
I
DLY
V
FLGh
Conditions
V
FLGl
Conditions
ch1, 2, 3
typ.
min.
max.
4.85
5.00
5.15
V
IN
=7V, I
O
=0.1A
0.5
I
O
≤
0.5A
30
V
IN
=6 to 15V, I
O
=0.1A
50
V
IN
=7V, I
O
=0 to 0.5A
±
0.5
V
IN
=7V, I
O
=5mA, T
j
=–10 to 100
°
C
20
V
IN
=7V, I
O
=0A
0.5
V
IN
=7V, V
C
1 to 4=0V
0.55
0.65
V
IN
=7V
2.0
0.7
50
V
C
=2.7V
–100
V
C
=0V
4.0
3.7
4.3
2.1
2.3
2.5
35
50
65
V
IN
–0.4
R
FLG
connected between FLG and V
IN
0.5
I
FLG
=1mA
SLA3007M
ch4
typ.
min.
max.
3.234
3.300
3.366
V
IN
=7V, I
O
=0.1A
2.0
I
O
≤
0.5A
30
V
IN
=6 to 15V, I
O
=0.1A
30
V
IN
=7V, I
O
=0 to 0.2A
±
0.3
V
IN
=7V, I
O
=5mA, T
j
=–10 to 100
°
C
–
–
0.55
0.65
V
IN
=7V
2.0
0.7
50
V
C
=2.7V
–100
V
C
=0V
–
–
–
–
–