![](http://datasheet.mmic.net.cn/300000/SL71051_datasheet_16211759/SL71051_3.png)
KSD-I5P001-000
3
SL71051
Electrical Characteristics
Ta = 25
℃
and V
CC
= 5V (unless otherwise specified)
Characteristic
Symbol
Test Condition
Min.
Typ.
Max.
Unit
[Total Current Consumption]
Ta = 25
℃
-
1.2
2
Total Supply Current – not taking
the output sinking current into account
I
CC
0 < Ta < 85
℃
-
1.5
-
[Voltage Control Loop]
Ta = 25
℃
1
3.5
-
Transconduction Gain (Vctrl).
Sink Current Only
G
mv
0 < Ta < 85
℃
-
2.5
-
/
Ta = 25
℃
1.198
1.210
1.222
Voltage Control Loop Reference
2)
V
ref
0 < Ta < 85
℃
1.186
1.210
1.234
V
Ta = 25
℃
-
50
-
Input Bias Current (Vctrl)
l
ibv
0 < Ta < 85
℃
-
100
-
[Current Control Loop]
Ta = 25
℃
1.5
7.0
-
Transconduction Gain (lctrl).
sink Current Only
G
mi
0 < Ta < 85
℃
-
-
-
/
Iout = 2.5
, Ta = 25
℃
196
200
204
Current Control Loop Reference
4)
V
sense
0 < Ta < 85
℃
192
-
208
Ta = 25
℃
-
25
-
Current out of pin ICTRL at -200mV
I
ibi
0 < Ta < 85
℃
-
30
-
[Output Stage]
Low output Voltage at 10mA
Sinking current
V
ol
-
-
200
-
Output Short Circuit Current.
Output to V
CC
. Sink Current Only
I
os
-
-
35
70
1) If the voltage on VCTRL (the negative input of the amplifier) is higher than the positive amplifier input
(Vref = 1.210V), and it is increased by 1mV, the sinking current at the output OUT will be increased by 3.5mA.
2) The internal voltage reference is set at 1.210V (bandgap reference). The voltage control loop precision takes
into account the cumulative effects of the internal voltage reference deviation as well as the input offset voltage
of the trans-conductance operational amplifier. The internal voltage reference is fixed by bandgap,
and trimmed to 0.5% accuracy at room temperature.
3) When the positive input at ICTRL is lower than -200mV, and the voltage is decreased by 1mV, the sinking
current at the output OUT will be increased by 7mA.
4) The internal current sense threshold is set to -200mV. The current control loop precision takes into account the
cumulative effects of the internal voltage reference deviation as well as the input offset voltage of the trans-