參數資料
型號: S8980
廠商: Hamamatsu Photonics
英文描述: Front-illuminated FFT-CCDs for X-ray imaging
中文描述: 前照明FFT的- CCD的X射線成像
文件頁數: 1/7頁
文件大?。?/td> 171K
代理商: S8980
Features
l
Sensor has X-ray monitoring photodiode
l
Compactness
5.1 mm thickness excluding I/O connector part
l
High dynamic range: 12 bit
l
Long-term stability
For use under 100,000 shots
(60 kVp, 30 mR X-ray irradiation)
l
Resolution: 20 Lp/mm
l
1500 (H) × 1000 (V) pixel format
l
Pixel size: 20 × 20 μm
l
Coupled with FOS for X-ray imaging
l
100 % fill factor
l
Low dark signal
l
Low readout noise
l
MPP operation
l
AC/DC X-ray source adapted
Applications
l
General X-ray imaging
l
Non-destructive inspection
l
Intra-oral X-ray imaging in dental diagnosis
I M A G E S E N S O R
CCD area image sensor
S8980, S8981-02
Front-illuminated FFT-CCDs for X-ray imaging
S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega (1500 × 1000) pixels each of
which is 20 × 20 μm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making
S8980 very reliable even over a long-term operation. The scintillator coated on the FOP is optimized to have high X-ray sensitivity and high
resolution (20 Lp/mm).
S8981-02 is an easy-to-use X-ray imaging module using S8980, with added functions such as a cable assembly and X-ray trigger circuit. S8981-
02 is advanced type for S8981 and adapted both AC and DC X-ray sources.
1
I
Selection guide
Type No.
Cooling
Number of
total pixels
Number of
active pixels
Active area
[mm (H) × mm (V)]
S8980
S8981-02
Non-cooled
1508 × 1002
1500 × 1000
30 × 20
I
General ratings
Parameter
S8980
S8981-02
CCD structure
Fill factor
Number of active pixels
Pixel size
Active area
Vertical clock phase
Horizontal clock phase
Output circuit
Dimensional outline
Reliability
Window
Other
Full frame transfer
100 %
1500 (H) × 1000 (V)
20 (H) × 20 (V) μm
30 (H) × 20 (V) mm
2 phase
2 phase
Emitter follower without load resistance
35.5 (H) × 23.2 (V) mm
100,000 shots at 60 kVp, 30 m Roentgen
Scintillator on 1.5 mm FOP
MPP mode (low dark current operation), module (S8981-02)
38.7 (H) × 26.3 (V) mm
相關PDF資料
PDF描述
S8981-02 Front-illuminated FFT-CCDs for X-ray imaging
S8982 CCD area image sensor Front-illuminated FFT-CCDs for X-ray imaging
S8984 CCD area image sensor Front-illuminated FFT-CCDs for X-ray imaging
S8985-02 CCD area image sensor Front-illuminated FFT-CCDs for X-ray imaging
S8B-EH Disconnectable Crimp style connectors
相關代理商/技術參數
參數描述
S8981-02 制造商:HAMAMATSU 制造商全稱:Hamamatsu Corporation 功能描述:Front-illuminated FFT-CCDs for X-ray imaging
S898-11-001-03-890800 制造商:MILL-MAX 功能描述:
S898-11-075-05-650400 制造商:Mill-Max Mfg Corp 功能描述:
S8982 制造商:HAMAMATSU 制造商全稱:Hamamatsu Corporation 功能描述:CCD area image sensor Front-illuminated FFT-CCDs for X-ray imaging
S898-22-002-77-710000 制造商:Mill-Max Mfg Corp 功能描述: