![](http://datasheet.mmic.net.cn/300000/S8658-01_datasheet_16209411/S8658-01_1.png)
S8658-01
Front-illuminated FFT-CCD for X-ray imaging
S8658-01 is a FFT-CCD area image sensor specifically developed for X-ray imaging. Since a FOS (Fiber Optic plate with Scintillator) to convert X-
rays into visible light is mounted on the CCD chip, X-ray images can be captured in fine detail. Three CCD chips are linearly arranged in close
proximity to form a long and narrow sensor format. Effective size of each active area is 73.728 (H) × 6.144 (V) mm
2
, so the overall active area
length of the three chips is up to 220 mm in length. Each CCD chip has 1536 × 128 pixels and the pixel size is 48 × 48 μm.
When used in TDI operation mode which is a special feature of this CCD image sensor, even X-ray images of a moving object can be clearly
acquired, making S8658-01 ideal for non-destructive inspection of products carried on a belt conveyor, etc. S8658-01 is pin compatible with
S8658: (Operating condition is a little bit changed from S8658)
Features
l
FFT-CCD coupled with FOS for X-ray imaging
l
1536 (H) × 128 (V) pixel format
l
Pixel size: 48 × 48 μm
l
Slit-like image of 220 mm long by aligning 3 CCD chips
together
l
Coupled with FOS for X-ray imaging
l
TDI (Time Delay Integration) operation
l
100 % fill factor
l
Wide dynamic range
l
Low dark current
l
MPP operation
Applications
l
General X-ray imaging
l
Non-destructive inspection
l
Dental panorama, cephalo
I M A G E S E N S O R
CCD area image sensor
PRELIMINARY DATA
Apr. 2003
I
Selection guide
Type No.
Cooling
Number of
total pixels
1536 × 128
Number of
active pixels
1536 × 128
Active area
[mm (H) × mm(V)]
73.728 × 6.144
S8658-01
Non-cooled
Note) As an input window, FOS is suited to S8658-01.
I
General ratings
Parameter
Specification
Full frame transfer or TDI
220 × 6 mm
100 %
1536 (H) × 128 (V) *
1
48 (H) × 48 (V) μm
73.728 (H) × 6.144 (V) mm *
1
2 phase and 2 line
2 phase and 2 line
Two-stage MOSFET source follower with load resistance
4 to 6 Lp/mm at 60 kVp, 10 m Roentgen
100,000 shots at 60 kVp, 10 m Roentgen
60 pin ceramic package
FOS (Fiber Optic plate with Scintillator)
CCD structure
X-ray sensitive area
Fill factor
Number of active pixels
Pixel size
CCD active area
Vertical clock phase
Horizontal clock phase
Output circuit
X-ray resolution
Reliability
Package
Window
*1: Number of active pixels per chip. Three chips are used.
1