Switch mode Power Supply
S82K
L-17
P
S
I
Overload Protection
The Power Supply is provided with an overload protection function that protects the load and the power supply from possible damage by overcur-
rent. When the output current rises above a set value (refer to the table below), the protection function is triggered, decreasing the output voltage.
When the output current falls within the rated range, the overload protection function is automatically cleared.
Note: 1.
When using the 7.5-W single-output models within the input voltage range between 90 and 110 VDC, the overload protection function
will operate at currents from 95% to 160% of the rated load current.
2.
When using the 90-W model at an ambient temperature exceeding 25
°
C, the overload protection function will operate at currents from
92% to 111% of the rated load current.
3.
When using the 100-W model with PFC in parallel operation, the overload protection function will operate at currents from 3.78 to 4.2 A.
65
70
90
240-W Model
Single-Unit Operation
Parallel-Unit Operation
Note:
100-VAC input: 85 to 132 VAC
L
Ambient temperature (
°
C)
L
Ambient temperature (
°
C)
Installation A
Installation A
90-W Models
Single-Unit Operation
L
Ambient temperature (
°
C)
Installation A
Installation B
240-W Model
Note:
100-VAC input: 85 to 132 VAC
S82K-P09024:
85-VAC input
S82K-P24024:
100-VAC input
(see note)
S82K-P24024:
100-VAC input
(see note)
(A) Standard (Vertical) Installation
(B) Horizontal Installation
Top
Top
S82K-
@@
Note:
The derating curve above can be ensured for
the above two kinds of installations.
(Not permitted for
240-W models.)
Single output
Dual
outputs
7.5 W
105% to
250% of rat-
ed load cur-
rent
Single output
3 W
7.5 W
15 W
30 W
50 W
90 W
100 W
240 W
Set value
105% to 160% of rated load
current (see note 1)
105% to 160% of rated load current
101% to
111% of rat-
ed load cur-
rent (see
notes 2 and
3)
Inverted L drop type, automatic reset
105% to 160% of rated load
current (see note 3)
Operation
Inverted L drop type, automatic reset
Inverted L drop/intermittent
operation type, automatic
reset