Battery Protection IC(for a 3-serial-cell pack)
S-8233B Series
21 August,1997
Seiko Instruments Inc.
8
(6) Measurement 6 Measurement circuit 3
Set S1 to ON, V1, V2, and V3 to 3.5 V, and V5 to 10.5 V under normal condition. V5/I5 is the internal
resistance between VCC and VMP (Rvcm).
Set S1 to ON, V1, V2, and V3 to 1.5 V, and V5 to 4.1 V under over discharge condition. (4.5-V5)/I5 is the
internal resistance between VSS and VMP (Rvsm).
(7) Measurement 7 Measurement circuit 4
Set S1 to ON, S2 to OFF, V1, V2, and V3 to 3.5 V, and V5 to 0 V under normal condition. Increase V6
from 0 V gradually. The V6 voltage when I6 = 10
μ
A is DOP'L' voltage (VD0 (L)).
Set S1 to OFF, S2 to ON, V1, V2, V3 to 3.5 V, and V5 to VIOV2+0.1 V under over current condition.
Increase V7 from 0 V gradually. The V7 voltage when I7 = 10
μ
A is the DOP'H' voltage (VDO (H)).
(8) Measurement 8 Measurement circuit 5
Set V1, V2, V3 to 3.5 V and V5 to 0 V under normal condition. Increase V6 from 0 V gradually. The V6
voltage when I1 = 10
μ
A is the COP'L' voltage (VC0 (L)).
(9) Measurement 9 Measurement circuit 6
Set V1, V2, V3 to 3.5 V under normal condition. Increase V1 from 3.5 V to 4.5 V immediately (within 10
μ
s). The time after V1 becomes 4.5 V until COP goes 'H' is the over charge detection delay time 1 (tCU1).
Set V1, V2, V3 to 3.5 V under normal condition. Decrease V1 from 3.5 V to 1.9 V immediately (within 10
μ
s). The time after V1 becomes 1.9 V until DOP goes 'H' is the over discharge detection delay time 1
(tDD1).
(10) Measurement 10 Measurement circuit 6
Set V1, V2, V3 to 3.5 V under normal condition. Increase V2 from 3.5 V to 4.5 V immediately (within 10
μ
s). The time after V2 becomes 4.5 V until COP goes 'H' is the over charge detection delay time 2
(tCU2).
Set V1, V2, V3 to 3.5 V under normal condition. Decrease V2 from 3.5 V to 1.9 V immediately (within 10
μ
s). The time after V2 becomes 1.9 V until DOP goes 'H' is the over discharge detection delay time 2
(tDD2).
(11) Measurement 11 Measurement circuit 6
Set V1, V2, V3 to 3.5 V under normal condition. Increase V3 from 3.5 V to 4.5 V immediately (within 10
μ
s). The time after V3 becomes 4.5 V until COP goes 'H' is the over charge detection delay time 3
(tCU3).
Set V1, V2, V3 to 3.5 V under normal condition. Decrease V3 from 3.5 V to 1.9 V immediately (within 10
μ
s). The time after V3 becomes 1.9 V until DOP goes 'H' is the over discharge detection delay time 3
(tDD3).
(12) Measurement 12 Measurement circuit 7
Set V1, V2, V3 to 3.5 V and S1 to OFF under normal condition. Increase V5 from 0 V to 0.55 V
immediately (within 10
μ
s). The time after V5 becomes 0.55 V until DOP goes 'H' is the over current
detection delay time 1 (tI0V1).
Set V1, V2, V3 to 3.5 V and S1 to OFF under normal condition. Increase V5 from 0 V to 0.75 V
immediately (within 10
μ
s). The time after V4 becomes 0.75 V until DOP goes 'H' is the over current
detection delay time 2 (tIOV2)
Set S1 to ON to inhibit over discharge detection. Set V1, V2, V3 to 4.0 V and increase V5 from 0 V to