S
2) 2 coil latching
2. Specifications
Characteristics
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
Type
Nominal coil
voltage
Set voltage
(at 20
°
C
68
°
F
)
Reset voltage
(at 20
°
C
68
°
F
)
Nominal operating
current [
±
10%]
(at 20
°
C
68
°
F
)
Coil resistance
[
±
10%]
(at 20
°
C
68
°
F
)
Nominal operating
power
(at 20
°
C
68
°
F
)
Coil inductance
Max. applied
voltage
(at 40
°
C
104
°
F
)
Set coil
Reset
coil
Set coil
Reset
coil
Set coil
Reset
coil
Set coil
Reset
coil
Approx.
10mH
Approx.
31mH
Approx.
40mH
Approx.
170mH
Approx.
680mH
Approx.
1,250mH
Standard
3V DC
70%V or less
of nominal
voltage
(Initial)
70%V or less
of nominal
voltage
(Initial)
66.7mA
66.7mA
45
45
200mW
200mW
Approx.
10mH
Approx.
31mH
Approx.
40mH
Approx.
170mH
Approx.
680mH
Approx.
1,250mH
5.5V DC
5V DC
38.5mA
38.5mA
130
130
192mW
192mW
9.0V DC
6V DC
33.7mA
33.7mA
180
180
200mW
200mW
11.0V DC
12V DC
16.7mA
16.7mA
720
720
200mW
200mW
22.0V DC
24V DC
8.4mA
8.4mA
2,850
2,850
202mW
202mW
44.0V DC
48V DC
7.4mA
7.4mA
6,500
6,500
355mW
355mW
65.0V DC
Item
Specifications
Contact
Arrangement
Contact resistance (Initial)
Electrostatic capacitance (initial)
Contact material
Thermal electromotive force (at nominal coil voltage)
(initial)
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Minimum operating power
Nominal operating power
Min. switching capacity (Reference value)*
1
2 Form A 2 Form B, 3 Form A 1 Form B, 4 Form A
Max. 50 m
(By voltage drop 6 V DC 1A)
Approx. 3pF
Au clad Ag alloy (Cd free)
Approx. 3
μ
V
Rating
4 A 250 V AC, 3 A 30 V DC
1,000 VA, 90 W
250 V AC, 48 V DC (30 to 48 V DC at less than 0.5 A)
4 A (AC), 3 A (DC)
100 mW (Single side stable, 2 coil latching)
200 mW (Single side stable, 2 coil latching)
100
μ
A 100 m V DC
Min. 10,000M
(at 500V DC)
Measurement at same location as “Breakdown voltage” section.
750 Vrms for 1min. (Detection current: 10mA.)
1,000 Vrms for 1min. (Detection current: 10mA.)
1,500 Vrms for 1min. (Detection current: 10mA.)
Max. 35
°
C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 4A.)
Max. 15 ms [15 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 10 ms [15 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Min. 490 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10
μ
s.)
Min. 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 3 mm (Detection time: 10
μ
s.)
10 to 55 Hz at double amplitude of 4 mm
Min. 10
8
(at 50 cps)
Min. 10
5
(4 A 250 V AC), Min. 2
×
10
5
(3 A 30 V DC) (at 20 times/min.)
Ambient temperature: –55
°
C to +65
°
C
–67
°
F to +149
°
F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min. for maximum load, 50 cps for low-level load (1 mA 1 V DC)
Approx. 8 g
.28 oz
Electrical
characteristics
Insulation resistance (Initial)
Breakdown voltage
(Initial)
Between open contacts
Between contact sets
Between contact and coil
Temperature rise (coil) (at 20
°
C
68
°
F
)
Operate time [Set time] (at 20
°
C
68
°
F
)
Release time [Reset time] (at 20
°
C
68
°
F
)
Mechanical
characteristics
Shock resistance
Functional
Destructive
Functional
Destructive
Vibration resistance
Expected life
Mechanical
Electrical
Conditions
Conditions for operation, transport and storage*
2
Max. operating speed
Unit weight
All Rights Reserved C
OPYRIGHT
Panasonic Electric Works Co., Ltd.