    參數(shù)資料
    型號: RX78K4
    英文描述: 78K/IV Series Real-Time OS Fundamental | User's Manual[01/1997]
    中文描述: 78K/IV系列實時操作系統(tǒng)的基本|用戶手冊[01/1997]
    文件頁數(shù): 35/96頁
    文件大?。?/td> 265K
    代理商: RX78K4
    CHAPTER 3 RX78K/IV BASIC OPERATIONS AND CONTROL BLOCKS
    26
    3.2.2
    Control blocks
    (1) Task control block (TCB)
    This control block is used by RX78K/IV to manage tasks. One control block of this type is assigned to each task.
    One TCB is 10 bytes long with the large model, and 8 bytes long with the small model.
    (2) Event flag (EVT)
    An event flag is a block that manages events that are used to synchronize tasks or make tasks wait.
    One event flag is 4 bytes long with the large model, and 2 bytes long with the small model.
    *
    If two or more tasks are waiting when the event flag is set, all the WAIT tasks enter the READY state.
    However, if a task exists that has issued “cwai
    _
    flg” and has entered the WAIT state, the flag is cleared after
    that task has been released from the WAIT state. After that, task state transitions do not take place.
    (3) Semaphore (SEM)
    A semaphore is a resource management block that is used to synchronize or mutually exclude tasks.
    One semaphore is 4 bytes long with the large model, and 2 bytes long with the small model.
    (4) Mail box (MBOX)
    A mail box is a control block that manages message communication between tasks.
    One mail box is 4 bytes long with the large model, and 2 bytes long with the small model.
    (5) Memory pool (MPL)
    The memory pool manages free memory blocks. Normally, memory blocks are used as message areas. When
    use it as a message area, be sure to set the size of one memory block to a multiple of 2. Even in cases other
    than messages, it is possible to secure only the portion of the memory blocks required for the relevant purpose.
    The size of the memory pool is the total of the free block management area and the memory blocks.
    The size of the free block management area is 4 bytes long with the large model, and 2 bytes long with the small
    model.
    (6) Cyclic handler control block (HCB)
    Cyclic handler control blocks are used by RX78K/IV to manage cyclic handlers. One cyclic handler is given one
    control block. The size of each cyclic handler control block is 10 bytes long with the large model, and 8 bytes
    long with the small model.
    相關PDF資料
    PDF描述
    RXB06150W TRANSISTOR | BJT | NPN | 15V V(BR)CEO | FO-91VAR
    RXB12350Y Bipolar NPN UHF/Microwave Transisitor
    RXE005 Poly Switch PTC DEVICES
    RXE010S Poly Switch PTC DEVICES
    RXE025 MULTISICHERUNG RXE 0.25A
    相關代理商/技術參數(shù)
    參數(shù)描述
    RX-7P 制造商:SUMIDA 制造商全稱:Sumida Corporation 功能描述:POWER INDUCTORS
    RX7P-NP-101K 制造商:SUMIDA 制造商全稱:Sumida Corporation 功能描述:POWER INDUCTORS
    RX7P-NP-102K 制造商:SUMIDA 制造商全稱:Sumida Corporation 功能描述:POWER INDUCTORS
    RX7P-NP-121K 制造商:SUMIDA 制造商全稱:Sumida Corporation 功能描述:POWER INDUCTORS
    RX7P-NP-122K 制造商:SUMIDA 制造商全稱:Sumida Corporation 功能描述:POWER INDUCTORS