![](http://datasheet.mmic.net.cn/390000/RT_datasheet_16831003/RT_1.png)
EC 36
www.recom-international.com
August 2002
Selection Guide
Part
Number
DIP 14
ECONOLINE - DC/DC-Converter
RT Series, 1 Watt, DIP14, Isolated Outputs (Dual Output)
Specifications (Core Operating Area) and Operating Temperature / Derating-Graph
Input Voltage
Input
Voltage
(VDC)
Output
Voltage
(V1VDC)
Output
Voltage
(V2VDC)
Ouput
Current
(mA)
Efficiency
(%)
RT-XX1.81.8
1.8, 3.3, 5, 9, 12, 24
1.8
1.8
278/278
70
RT-XX3.33.3
1.8, 3.3, 5, 9, 12, 24
3.3
3.3
132/152
70
RT-XX0505
1.8, 3.3, 5, 9, 12, 24
5
5
100/100
70-78
RT-XX0909
1.8, 3.3, 5, 9, 12, 24
9
9
55/55
75-80
RT-XX1212
1.8, 3.3, 5 9, 12, 24
12
12
42/42
78-84
RT-XX1515
1.8, 3.3, 5, 9, 12, 24
15
15
33/33
80-84
RT-XX0524
1.8, 3.3, 5, 9, 12, 24
24
24
21/21
80-84
±10%
Input Filter
Capacitor Type
Output Voltage Accuracy
±5%
Line Voltage Regulation
1,2%/1% V Input
Load Voltage Regulation
(10% to 100% full load)
1.8V, 3.3V output types
5V output type
9V, 12V, 15V, 24V output types
20% max.
15% max.
10% max.
Ripple and Noise (20MHz limited)
100mVp-p max.
Efficiency at Full Load
70% min.
Isolation Voltage
1.000VDC min.
Isolation Resistance (Viso = 500VDC)
10 G
min.
Isolation Capacitance
20pF min./94pF max.
Short Circuit Protection
1 Second
Switching Frequency at Full Load
100kHz typ.
Operating Temperature
–40°C to +85°C (see Graph)
Storage Temperature
-55°C to +125°C
Package Weight
2.7g
●
Twin Independent Outputs
●
Output/Output Isolation 1kVDC
●
Power Sharing on Outputs
●
Input/Output Isolation 1kVDC
●
No Heatsink Required
●
Toroidal Magnetics
●
No Extern. Components Required
●
Custom Solutions Available
●
UL94V-0 Package Material
●
Efficiency to 80%
Features
O
2.0
1.5
0.5
1.0
100
50
0
-40
85
125
150
Operating Temperature C
Safe Operating Area