![](http://datasheet.mmic.net.cn/260000/RS-053-3D_datasheet_15969260/RS-053-3D_2.png)
!
Derating-Graph
(Ambient Temperature)
Typical Characteristics
Description
Input Voltage Range
2:1
Output Accuracy
Single output
Dual output
Single output
Dual output
±1%
±2%
Line Voltage Regulation
±0.2% max.
±0.5% max.
Load Voltage Regulation
(25% to 100% full load)
Output Ripple and Noise (20MHz limited)
Single & Dual output
±0.5% typ.
50mVp-p max.
Switching Frequency (at full Load)
Single output
Dual output
85kHz min.
100kHz min. / 700kHz max.
70% min. / 80% typ.
50mW min. / 139mW typ. / 250mW max.
(tested for 1 second)
H2
H3
(long term isolation)
Single
10pF min. / 40pF typ. / 60pF max.
Single
5pF min. / 30pF typ. / 60pF max.
Dual
120pF min. / 170pF typ. / 250pF max.
Dual
5pF min. / 30pF typ. / 60pF max.
Efficiency at Full Load
No Load Power Consumption
Isolation Voltage
1000VDC min.
2000VDC min.
3000VDC min.
see Application Notes
Rated Working Voltage
Isolation Capacitance (1000V version)
Isolation Capacitance (H2 and H3)
Isolation Capacitance (1000V version)
Isolation Capacitance (H2 and H3)
Isolation Resistance
1G
min.
Short Circuit Protection
Continuous
Operating Temperature Range
–40°C to +85°C
Storage Temperature Range
–55°C to +125°C
Relative Humidity
Package Weight
95% RH
4.8g
MTBF (+25°C)
using MIL-HDBK 217F
1398 x 10
3
hours
(+85°C)
using MIL-HDBK 217F
210 x 10
3
hours
Electrical Specifications
(measured at T
A
= 25°C, at nominal input voltage and rated output current unless otherwise specified)
RS
Series
ECONOLINE
DC/DC-Converter
"
"##$%&'
(#
)
RS-24xx
*
+
+,
,
+
+
-.(.
)
RS-types
High power-density, an industrial temperature range of -40°C to +85°C and extra features like Remote-On-
Off-control are just some of the characteristics of this converter, ideal for highly sophisticated industrial
designs. The RS series is available with isolation of 2kV or 3kV by chosing option "/H2" or "/H3" in which case
it is also ideal for medical applications which additionally require EN-60601-1 certification.
}
Detailed Information see
Application Notes chapter "MTBF"
January-2007
89