![](http://datasheet.mmic.net.cn/260000/RP50-2405S_datasheet_15968900/RP50-2405S_1.png)
140
www.recom-international.com
April-2005
50 Watt
Single
Output
INNOLINE
DC/DC-Converter
RP50-S
Series
●
Single Outputs up to 15A
●
Input/Output 1.6kVDC Isolation
●
Adjustable Output Voltage
●
No Minimum Load
●
Under -Voltage Lockout
●
Industry Standard Footprint
●
Fixed Operating Frequency
●
Halt Tested
●
Compact 61.0 x 57.91 x 12.7mm Package
●
High Efficiency to 91%
Features
Selection Guide
Notes:
Part Input Output Output Line
Number Voltage Voltage Current Regulation Regulation Current
Single Output
(VDC) (VDC) (A) (mV) (mV) (A) %
Load Input Efficiency
RP50-241.8S 18 – 36 1.8 15 4 6 1.36 86
RP50-242.5S 18 – 36 2.5 15 5 8 1.86 87
RP50-243.3S 18 – 36 3.3 15 7 10 2.40 89
RP50-2405S 18 – 36 5 10 10 15 2.40 90
RP50-2415S 18 – 36 15 3.3 30 45 2.40 89
RP50-481.8S 36 – 75 1.8 15 4 6 1.36 87
RP50-482.5S 36 – 75 2.5 15 5 8 1.86 89
RP50-483.3S 36 – 75 3.3 15 7 10 2.40 90
RP50-4805S 36 – 75 5 10 10 15 2.40 91
RP50-4815S 36 – 75 15 3.3 30 45 2.40 90
1. Maximum output deviation is 10% inclusive of remote sense. If remote sense is not being used,
the +Vsense should be connected to its corresponding +Vout
2. Measured with a 1uF M/C and a 10uF T/C.
3.An external filter capacitor is required for normal operation.The capacitor should be capable of handing 1A
ripple current for 48V/24V models. RECOM suggests: Nippon chemi-con KMF series, 220μF/100V, ESR 90m
.
4.The negative/ positive logic and pin length are optional ( see table ).The pin voltage is referenced to
negative input.
5. Heat sink is optional and P/N: 7G-0021, 7G-0022, 7G-0023, 7G-0024.
6.The RP50 meets level A and level B conducted emissions only with external components connected before
the input pin to the converter.
7. Maximum value at nominal input voltage and full load.
8.Typical value at nominal input voltage and full load.
9. BASEPLATE GROUNDING : Base-plate should be grounded at one of the four screw bolts prior to operation.
10.The converter is provided by basic insulation.
11.“N” for Negative remote ON/OFF.
12.“P” for
Positive
remote ON/OFF.