![](http://datasheet.mmic.net.cn/260000/RP20-483-3SE_datasheet_15968677/RP20-483-3SE_3.png)
230
www.recom-international.com
April-2005
Specifications
(typical at nominal input and 25°C unless otherwise noted)
POWERLINE
DC/DC-Converter
RP20-S_D_TE
Series
Minimum Load (see Note 1)
Line Regulation (LL-HL at full load)
10% of FL
±0.2%
±0.5%
Single (W)
Dual (W)
Triple 3.3V, 5V
Auxiliary
Single
Dual
Triple 3.3V, 5V
Auxiliary
Dual
Triple 3.3V, 5V
Auxiliary
Single
Dual
Triple 3.3V, 5V
Auxiliary
±1%
±5%
±0.5%
±3%
±2%
±5%
±5%
±2%
±5%
75mVp-p
100mVp-p
50mVp-p
1% of Vout
Load Regulation (25% to 100% FL)
Cross Regulation (Note 9)
Ripple and Noise (20MHz bandwith)
Temperature Coefficient
±0.02%/°C, max.
Transient Response (25% load step change)
Over Voltage Protection
Zener diode clamp (only single)
500μS
3.9V
6.2V
15V
18V
3.3V
5V
12V
15V
Short Circuit Protection
Hiccup, automatic recovery
Efficiency
see Selection Guide“ table
Isolation Voltage
1.600VDC min.
Isolation Resistance
10
9
min.
Isolation Capacitance
300pF max.
Operating Frequency
300kHz typ.
Approved to Safety Standards (see note 10)
UL 1950, EN60950
Operating Temperature Range
-40°C to +85°C(with derating)
Maximum Case Temperature
+100°C
Storage Temperature Range
Thermal Impedance
-55°C to +105°C
10°C/Watt
8.24°C/Watt
Natural convection
Natural convection with Heat Sink
Thermal Shock
MIL-STD-810D
Vibration
10-55Hz, 2G, 30 Min. along X,Y and Z
Relative Humidity
5% to 95% RH
Case Material
Nickel-Coated copper
Base Material
Non-conductive black plastic
Potting Material
Conducted Emissions
Radiated Emissions
ESD
Radiated Immunity
Fast Transient
Surge
Conducted Immunity
Epoxy (UL94-V0)
EN55022
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Level A
Level A
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
continued on next page