RENCO ELECTRONICS, INC.
595 International Place, Rockledge, FL 32955-4200 USA
(321) 637-1000 Toll Free Engineering Hot line 800-645-5828
Fax: (321) 637-1600
Web Site:www.rencousa.com
SINCE 1955
E-mail:sales@rencousa.com
53
RL-1361
COMMON MODE CHOKES
EE CORE DESIGN
Renco Common Mode Chokes are designed
to help meet U.S. and International requirements
for safety and EMI. By placing these chokes at
the inputs of electrical equipment or circuits
EMI feedback can be kept within specified limits.
These low priced Common Mode Chokes are
available in a wide range of standard
inductances and current ratings from 100mA
to 5.5Amps.
The PC mounting makes them easy to
incorporate in equipment.
Application:
Under normal operating conditions, power
supplied through the Common Mode Choke is
balanced. When the equipment in which the
choke is utilized generates electrical noise due
to operation of relays, triacs, SCRs, etc., these
transient noise pulses cause an imbalance in
the power line current. Since the coils of the
Common Mode Choke are out of phase with
each other, noise being fed back to the power
level and does not interfere with other equipment
operating on the same power line.
Specifications:
Windings balanced within 1%
@+80
°
C ambient, +40
°
C rise
-55
°
C to +130
°
C operating temperature
2000 VAC Hipot winding to winding
1500 VAC Hipot winding to core
All specifications measured @ +20
°
C
Inductance values:
±
25% @ 1KHz
Special Features:
Low Profile
Varnish Impregnated
MTL Used Class B 130
°
C
Nonlisted Values Available
MIL Spec. and Encapsulation Available