![](http://datasheet.mmic.net.cn/160000/RPV0050MD601V410100_datasheet_9720858/RPV0050MD601V410100_7.png)
7
How to order
MTS Sensors Product Specification 550992 D
SENSOR MODEL
RP = Profile style
RH = Hydraulic rod style
RF = Flexible style
HOUSING STYLE
Model RP sensor only (magnet included):
S =
Captive-sliding magnet with joint at top (part no. 252182)
V =
Captive-sliding magnet with joint at front (part no. 252184)
M =
Floating magnet, open ring (part no. 251416-2)
Model RH sensor only (magnet must be ordered separately):
T =
US customary threads, raised-faced hex, and pressure tube
S =
US customary threads, flat-faced hex, and pressure tube
M =
Metric threads, flat-faced hex, and pressure tube
B =
Sensor cartridge only (no pressure tube, stroke lengths < 72 in.)
Model RF sensor only, (reference the flex housing style section in the
Industrial Catalog, part number 551075), magnet must be ordered separately:
S =
US customary threads, flat-faced hex
M =
Metric threads, flat-faced hex
STROKE LENGTH
— — — — M = Millimeters (Encode in 5 mm increments)
— — — . — U = Inches and tenths (Encode in 0.1 in. increments)
CONNECTION TYPE
Integral connector
D60 = 6-pin DIN, male, standard
Integral cables
R — — = Integral cable, PVC jacket, pigtail termination
Cable length options:
— — = Encode in feet if using US customary stroke length,
encode in meters if using metric stroke length
Range = 1 (01) to 99 (99) ft. or 1 (01) to 30 (30) meters.
INPUT VOLTAGE
1 = +24 Vdc (+20% - 15%)
OUTPUT (13 - 19) 3 to 7 digit code depending on output selected (Please note that selections below are continued on page 8)
1 output channel with 1 magnet (3 digit code)
Output #1 = magnet position
V01 = 0 to +10 Vdc
A01 = 4 to 20 mA
V11 = +10 to 0 Vdc
A11 = 20 to 4 mA
V21 = -10 to +10 Vdc
A21 = 0 to 20 mA
V31 = +10 to -10 Vdc
A31 = 20 to 0 mA
2 output channels with 2 magnets * (3 digit code)
Output #1 = magnet #1 position
Output #2 = magnet #2 position
V02 = 0 to +10 Vdc
0 to +10 Vdc
V12 = +10 to 0 Vdc
+10 to 0 Vdc
V22 = -10 to +10 Vdc
-10 to +10 Vdc
V32 = +10 to -10 Vdc
+10 to -10 Vdc
A02 = 4 to 20 mA
4 to 20 mA
A12 = 20 to 4 mA
20 to 4 mA
A22 = 0 to 20 mA
0 to 20 mA
A32 = 20 to 0 mA
20 to 0 mA
*
Standard factory settings for the setpoint values are the same for both magnets, i.e. both magnets have setpoint 1 at the null position, and setpoint 2 at the
start of the dead zone. If needed, the setpoint values for each magnet can be reprogrammed in the field to best fit the application, (see page 4 for more infor-
mation). For proper sensor output, the minimum allowed distance between the magnets is 3.0 in. (76 mm).
Stroke length notes:
Profile (RP) stroke range = 50 - 5080 mm. (2 - 200 in. )
Rod (RH) stroke range = 50 - 7620 mm. (2 - 300 in.)
R
Cable length note:
MTS recommends the maximum integral cable length to be 10
meters or 33 feet. Cables greater than 10 meters in length are
available, however, proper care must be taken during handling
and installation.
3 to 7 digit code depending on output selected
1
2
3
4
5
6
7
8
9
10
11
12
13 14
15
16 17
18 19
1