How to order (continued)
8
MTS Sensors Product Specification 550992 D
OUTPUT (13 - 19) 3 to 7 digit code depending on output selected (Please note that selections below are continued from the previous page)
2 output channels with 1 magnet (7 digit code, fill in the blanks with the desired maximum speed value as described below)
Output #1 = magnet position
Output #2 = speed magnitude
V01 — — — — = 0 to +10 Vdc
+10 (towards head)
0 (at rest)
+10 (towards tip) Vdc
V11 — — — — = +10 to 0 Vdc
+10 (towards head)
0 (at rest)
+10 (towards tip) Vdc
A01 — — — — = 4 to 20 mA
20 (towards head)
4 (at rest)
20 (towards tip) mA
A11 — — — — = 20 to 4 mA
20 (towards head)
4 (at rest)
20 (towards tip) mA
Output #1 = magnet position
Output #2 = Velocity (speed with direction)
V41 — — — — = 0 to +10 Vdc
0 (towards head)
5 (at rest)
+10 (towards tip) Vdc
V51 — — — — = +10 to 0 Vdc
+10 (towards head)
5 (at rest)
0 (towards tip) Vdc
V61 — — — — = 0 to +10 Vdc
-10 (towards head)
0 (at rest)
+10 (towards tip) Vdc
V71 — — — — = +10 to 0 Vdc
+10 (towards head)
0 (at rest)
-10 (towards tip) Vdc
V81 — — — — = -10 to +10 Vdc
-10 (towards head)
0 (at rest)
+10 (towards tip) Vdc
V91 — — — — = +10 to -10 Vdc
+10 (towards head)
0 (at rest)
-10 (towards tip) Vdc
A41 — — — — = 4 to 20 mA
4 (towards head)
12 (at rest) 20 (towards tip) mA
A51 — — — — = 20 to 4 mA
20 (towards head)
12 (at rest) 4 (towards tip) mA
Output #1 = magnet position (forward-acting)
Output #2 = magnet position (reverse-acting)
V03
= 0 to +10 Vdc (3 digit code)
+10 to 0 Vdc
For sensor models with speed output, fill in the blanks for the desired maximum speed value as shown below.
For US customary stroke lengths, encode speed for in./s as follows:
— — — — = Speed output max. (fill in remaining 4 blanks with desired max. speed value)
Available range for US customary stroke lengths is 1.0 to 400.0 in./s, (0010 … 4000)
Example: For max. speed of 12.0 in./s, and output produced =
[-10(towards head) … 0(at rest) … +10(towards tip) Volts] Encode: V 6 1 0 1 2 0 or V 8 1 0 1 2 0
For metric stroke lengths, encode speed for m/s (range 1) or mm/s (range 2) as follows:
Speed range #1
, ( 0
)
0
= Speed output max. (fill in the remaining 3 blanks with desired max. speed value)
Speed range 1 for metric stroke lengths is 0.1 to 10.0 m/s, (0001 … 0100)
Example: For max. speed of 5.5 m/s, and output produced =
[+10(towards head) … 0(at rest) … +10(towards tip) Volts], Encode: V 0 1 0 0 5 5
Speed range #2
, ( 1
)
1
= Speed output max. (fill in remaining 3 blanks with desired max. speed value)
Speed range 2 for metric stroke lengths is 25 to 90 mm/s, (1025 … 1090)
Example: For max. speed of 50 mm/s, and output produced =
[4(towards head) … 12(at rest) … 20(towards tip) mA], Encode: A 4 1 1 0 5 0
Field programming notes:
1) Sensor models ordered with one output channel can not be reprogrammed in the field to provide a second output channel.
2) Sensor models ordered with positive only output voltages can not be reprogrammed in the field to include negative output voltages.
3) Sensor models ordered with both positive and negative output voltages can be reprogrammed in the field for positive only voltages, or negative only
voltages, however, output resolution is then reduced.
— — — —
— — — . —
— — — —