4
Specifications are subject to change without notice (30.06.1999)
RC 24 .. -D 06, RC 44 .. -D 12
Applications
Timing
Initial turn-on
The line voltage must be pre-
sent at least 1 period before
the input voltage is applied.
Repetitive turn-on
The input voltage must be
lower than the drop out volt-
age limit at least 1 period be-
fore it is reapplied.
As transformers can have va-
rying stray inductances and
stray capacitances, it is al-
ways advisable to use external
overvoltage protection.
Varistor diameter:
≤
20 mm
Varistor voltage for 240 V SSR:
250 VAC (RV 02)
Varistor voltage for 440 V SSR:
480 VAC (RV 05)
Overvoltage protection
Dimensions
Housing Specifications
Weight
Housing material
Base plate
Potting compound
Relay
Mounting screws
Mounting torque
Control terminal
Mounting screws
Mounting torque
Power terminal
Mounting screws
Mounting torque
Approx. 110 g
Noryl GFN 1, black
Aluminium
Polyurethane
M5
≤
1.5 Nm
M3 x 6
≤
0.5 Nm
M5 x 6
≤
2.4 Nm
Accessories
Protection cover
Heatsinks
DIN rail adapter
Varistors
Fuses
Input
voltage
Load
Supply
voltage
** =
±
0.4 mm
***=
±
0.5 mm
**
**
*
*
*
*
Line voltage
Output voltage
Input voltage
Min. 1 period
Input voltage
Min. 1 period
For further information refer
to "General Accessories".