2
Specifications are subject to change without notice (30.06.1999)
Supply voltage range
Supply current @ 24 VDC
Response time pick-up @ 50 Hz
Response time drop-out @ 50 Hz
Active high control input
Pick-up voltage
Drop-out voltage
Input current (Vc = 32 V)
Active low control input
Pick-up voltage
Drop-out voltage
Input current (Vcc = 32 V)
20 to 32 VDC
≤
40 mA DC
≤
10 ms
≤
10 ms
Typ. 7 VDC
Typ. 6.8 VDC
≤
4 mA
Typ. Vcc - 10 VDC
Typ. Vcc - 10 VDC
≤
4 mA
RA.... .....S
PNP Alarm output
Alarm output voltage open
Alarm output voltage @ 100 mA
Alarm output current
NPN Alarm output
Alarm output voltage open
Alarm output voltage @ 100 mA
Alarm output current
0 VDC
Vcc - 2 VDC
≤
100 mA
≤
32 VDC
2 VDC
≤
100 mA
RA..25.06..S
RA..50.06..S
RA..90.10..S
Rated operational current AC 1
Min. operational load current
Non-rep. surge current t=10 ms
Off-state leakage current
@ rated voltage and frequency
I
2
t for fusing t=1-10 ms
Critical dv/dt
≤
25 Arms
≤
200 mA
≤
250 A
p
≤
50 Arms
≤
200 mA
≤
600 A
p
≤
90 Arms
≤
200 mA
≤
1000 A
p
≤
6 mA
≤
310 A
2
s
≥
500 V/μs
≤
6 mA
≤
1800 A
2
s
≥
500 V/μs
≤
6 mA
≤
5000 A
2
s
≥
500 V/μs
RA12...06..S
RA23...06..S
RA40...10..S
Operational voltage range
Non-rep. peak voltage
Zero voltage turn-on
Operational frequency range
Power factor cos
CE-marking
40 to 140 VACrms
600 V
p
≤
15 V
45 to 65 Hz
≥
0.5 @ 120 VACrms
Yes
85 to 265 VACrms
600 V
p
≤
15 V
45 to 65 Hz
≥
0.5 @ 230 VACrms
Yes
150 to 440 VACrms
1000 V
p
≤
15 V
45 to 65 Hz
≥
0.5 @ 400 VACrms
Yes
RA12...06..S
RA23...06..S
RA40...10..S
Current
Sensed load current
Non-sensed leakage current
Voltage
Sensed line voltage
Non-sensed line voltage
Timing
Response time from fault to
alarm output
Short-circuit of semiconductor
≥
50 mA
≤
20 mA
≥
50 mA
≤
20 mA
≥
50 mA
≤
20 mA
≥
60 Vrms
≤
30 Vrms
≥
120 Vrms
≤
50 Vrms
≥
150 Vrms
≤
80 Vrms
≤
100 ms
Will be sensed
≤
100 ms
Will be sensed
≤
100 ms
Will be sensed
General Specifications
Control Specifications
Output Specifications
Sense Specifications