33
Q-TECH Corporation - 10150 W. Jefferson Boulevard, Culver City 90232 - Tel: 310-836-7900 - Fax: 310-836-2157 - www.q-tech.com
Q-TECH
CORPORATION
QT78 SERIES
HIGH-RELIABILITY MINIATURE CLOCK OSCILLATORS
1.8 to 5.0Vdc
-
15kHz to 150MHz
QT78 (RevisionB,January2008)(ECO#9217)
PackagingOptions
OtherOptionsAvailableForAnAdditionalCharge
OrderingInformation
Frequencystabilityvs.temperaturecodesmaynotbeavailableinallfrequencies.
ForNon-Standardrequirements,contactQ-TechCorporationatSales@Q-Tech.com
Specificationssubjecttochangewithoutpriornotice.
Standardpackaginginanti-staticplastictube(60pcs/tube)
TapeandReel(800pcs/reel)isavailableforanadditional
charge.
SolderDipSn/Pb60/40%
P.I.N.D.test
AC=ACMOS
HC=HCMOS
T =TTL
QT78XX—D—XX—M—85.000MHz
Outputfrequency
Screenedto
MIL-PRF-55310,levelB
(Leftblankifnoscreening)
1 = ± 100ppm at 0C to +70C
4 = ± 50ppm at 0C to +70C
5 = ± 25ppm at -20C to +70C
6 = ± 50ppm at -55C to +105C
9 = ± 50ppm at -55C to +125C
10 = ± 100ppm at -55C to +125C
11 = ± 50ppm at -40C to +85C
12 = ± 100ppm at -40C to +85C
14 = ± 20ppm at -20C to +70C
15 = ± 25ppm at -40C to +85C
TristateOptionD
(LeftblankifnoTristate)
5.0Vdc
QT78L—D—XX—M—150.000MHz
Outputfrequency
Screenedto
MIL-PRF-55310,levelB
(Leftblankifnoscreening)
1 = ± 100ppm at 0C to +70C
4 = ± 50ppm at 0C to +70C
5 = ± 25ppm at -20C to +70C
6 = ± 50ppm at -55C to +105C
9 = ± 50ppm at -55C to +125C
10 = ± 100ppm at -55C to +125C
11 = ± 50ppm at -40C to +85C
12 = ± 100ppm at -40C to +85C
14 = ± 20ppm at -20C to +70C
15 = ± 25ppm at -40C to +85C
TristateOptionD
(LeftblankifnoTristate)
3.3Vdc
QT78N—D—XX—M—133.000MHz
Outputfrequency
Screenedto
MIL-PRF-55310,levelB
(Leftblankifnoscreening)
1 = ± 100ppm at 0C to +70C
4 = ± 50ppm at 0C to +70C
5 = ± 25ppm at -20C to +70C
6 = ± 50ppm at -55C to +105C
9 = ± 50ppm at -55C to +125C
10 = ± 100ppm at -55C to +125C
11 = ± 50ppm at -40C to +85C
12 = ± 100ppm at -40C to +85C
14 = ± 20ppm at -20C to +70C
15 = ± 25ppm at -40C to +85C
TristateOptionD
(LeftblankifnoTristate)
2.5Vdc
QT78R—D—XX—M—100.000MHz
Outputfrequency
Screenedto
MIL-PRF-55310,levelB
(Leftblankifnoscreening)
1 = ± 100ppm at 0C to +70C
4 = ± 50ppm at 0C to +70C
5 = ± 25ppm at -20C to +70C
6 = ± 50ppm at -55C to +105C
9 = ± 50ppm at -55C to +125C
10 = ± 100ppm at -55C to +125C
11 = ± 50ppm at -40C to +85C
12 = ± 100ppm at -40C to +85C
14 = ± 20ppm at -20C to +70C
15 = ± 25ppm at -40C to +85C
TristateOptionD
(LeftblankifnoTristate)
1.8Vdc