Electrical Specifications
Alternistor Triacs
4-4
Teccor Electronics, Inc.
(972) 580-7777
General Notes
All measurements are made at 60Hz with a resistive load at an
ambient temperature of +25°C unless specified otherwise.
Operating temperature range (TJ) is -40°C to +125°C except 0°C to
+125°C for FastPaks.
Storage temperature range (TS) is -40°C to +125°C except -20°C to
+125°C for FastPaks.
Lead solder temperature is a maximum of 230°C for 10 seconds
maximum
≥ 1/16" (1.59mm) from case.
The case temperature (TC) is measured as shown on the dimen-
catalog.
Electrical Specification Notes
(1)
For either polarity of MT2 with reference to MT1 terminal.
(2)
For either polarity of gate voltage (VGT) with reference to MT1 ter-
minal.
(3)
See Definition of Quadrants.
(4)
See Figures
4.1 through
4.4 for current rating at specific operating
temperature.
(5)
See Figures 4.5 and 4.6 for iT and vT. (6)
(7)
(8)
(9)
See Figures
4.10 an
d 4.11 for surge rating with specific durations.
(11) See package outlines for lead form configurations. When ordering
special lead forming, add type number as suffix to part number.
(12) Initial on-state current = 400 mA(DC) for 15-40A devices and
100mA for 6-12 Amp devices.
(13) See Figures
4.1 throug
h 4.4 for maximum allowable case temper-
ature at maximum rated current.
(14) Pulse width
≤ 10s.
(15) For 6-12 Amp devices, RL = 60; 15 Amp and above, RL = 30
(16) 40 Amp pin terminal leads on K package can run 100°C to 125°C.
(17) Alternistor does not turn on in Quadrant IV.
(18) Tc = TJ for test conditions in off-state
(19) IGT = 200 mA for 6-12 Amp devices and 500 mA for 15-40 Amp
devices with gate pulse having rise time of
≤ 0.1 microsecond.
Gate Characteristics
Teccor triacs may be turned on in the following ways:
With in-phase signals (using standard AC line) Quadrants I and
III are used.
By applying unipolar pulses (gate always negative)—with nega-
tive gate pulses Quadrants II and III are used.
In all cases, if maximum surge capability is required, gate pulses
should be a minimum of one magnitude above minimum IGT rat-
ing with a steep rising waveform (
≤1s rise time).
Definition of Quadrants
Electrical Isolation
Teccor’s isolated Alternistor packages will withstand a minimum
high potential test of 2500 VAC (RMS) from leads to mounting
tab, over the operating temperature range of the device. See iso-
lation table below for standard and optional isolation ratings.
* For 4000V isolation, use V suffix in part number.
** UL Recognized File E71639
** UL Recognized Product per UL File E71639.
ELECTRICAL ISOLATION
FROM LEADS TO MOUNTING TAB **
VAC
(RMS)
Isolated
TO-218AC
Isolated
FASTPAK
Isolated
TO-220AB
Isolated
TO-218X
2500
Standard
4000
N/A
Optional *
N/A
MT2 POSITIVE
(Positive Half Cycle)
MT2 NEGATIVE
(Negative Half Cycle)
MT1
MT2
+ I
GT
REF
MT1
I
GT
GATE
MT2
REF
MT1
MT2
REF
MT1
MT2
REF
(
-)
I
GT
GATE
(+)
I
GT -
I
GT
GATE
(
-)
I
GT
GATE
(+)
+
-
THERMAL RESISTANCE (Steady State)
RθJC
oC/W(TYP)
Type
K
Isolated**
TO-218AC
P
FastPak**
TO-3BASE
L
Isolated**
THERMOTAB
TO-220AB
R
Non-Isolated
TO-220AB
J
Isolated**
TO-218X
6 amps
3.3 [50]
2.1 [45]
8 amps
2.8
1.8
10 amps
2.6
1.5
12 amps
2.3
1.4
15 amps
2.1
1.3
25 amps
1.35
1.3
2.0
1.1
1.32
40 amps
0.97
0.9
0.95
G
MT2
MT1
MT2
G
MT1
G
MT2
MT1
G
MT2