PowerBlock Micro-Miniature 5 Watt Switching Power Supplies
pwC
series
www.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE pACIFIC: 886-2-26983458
ASTRODYNE EUROpE: 353 51 561060
INpUT SpECIFICATIONS
Input Voltage (AC/DC)
Input Frequency
Inrush Current
90-264VAC/110-340VDC
Nominal: 100-240VAC
47-440 Hz, 50-60Hz Nom.
20A @ 115VAC, typ
40A @ 200VAC, typ
OUTpUT SpECIFICATIONS
Output Voltage/Current (Note 5) See Model Chart
Preset Accuracy (Note 8)
Load Regulation (Note 6)
20%-FL
Line Regulation (Note 7)
Temperature Coefficient
Ripple/Noise(20Mhz BW)
Overvoltage Protection
Hold Up Time
Short Circuit Protection
OverTemp Protection
+/-1%, typ
3.3V & 5V:+/-1%, max.
12V, 15V, & 24V:+/-0.5%, max.
3.3V & 5V:+/-1%, max.
12V, 15V, & 24V:+/-0.5%,max.
+/-0.03%/°C (0-50°C, typ.)
150mV Pk-Pk, typ (Notes 1, 2 & 9)
Clamp
*
10mS, typ
Latching, Recovering
*
Latching, Recovering
*
GENERAL SpECIFICATIONS
Input-Out Isolation (Note 3)
Output-Ground Isolation
Input-Ground Isolation
Switching Frequency
Efficiency (@ Full Load)
Safety
EMI
3000VAC
1000VAC
2500VAC
132 Khz, fixed, typ
See Model Chart
UL60950, EN60950
EN55022
ENVIRONMENTAL SpECIFICATIONS
Oper. Temperature (Note 4)
PWC-xx, PWC-xxS
PWC-xxE
Relative Humidity
Storage Temperature
-10 to +50°C FL
-25 to +65°C FL
See Derate Curves
0-95%, Non-Condensing
-40 to +85°C
*
pHYSICAL SpECIFICATIONS
Construction
Weight
Notes:
1. All measurements should be made directly at the terminals of the
power supply
2. Ripple and noise dependent upon output voltage as specified per
particular model.
3. Isolation for up to 1 minute duration.
4. Specified for free air convection cooling.
5. Minimum load is not required for proper operation.
6. Load Regulation is measured from 5% to Full Load.
7. Line Regulation measured from High Line to Low Line.
8. Preset Accuracy measured at nominal load, 120VAC input.
9. O/P Noise measured directly at the pins/terminals at nominal load,
0.1uF bypass and 47uF electrolytic, pk-pk @ 20MHz bandwidth.
10. 100% Production Tested
Open Frame or Encapsulated
Open Frame: 1.0 oz (28g)
Encapsulated: 1.5 oz. (42g)
*
These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
All specifications are typical at nominal input, full load, and 25DegC unless
otherwise noted
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.