![](http://datasheet.mmic.net.cn/260000/PVX-2110_datasheet_15960012/PVX-2110_2.png)
THE PULSE OF THE FUTURE
Directed Energy, Inc.
An
IXYS
Company
2401 Research Blvd., Suite 108
Fort Collins, CO USA 80526
970-493-1901 Fax: 970-493-1903
Email: deiinfo@directedenergy.com
Web: http://www.directedenergy.com
SPECIFICATIONS
(All specifications measured into a 5
load connected with 4 feet (~1.2M) 5
cable provided with the PVX-2110)
Doc #9200-0216 Rev 3
Directed Energy, Inc. 2000
OUTPUT
Output Voltage Polarity
Maximum Value
Minimum Value
Means Of Adjustment
Maximum Output Current
Pulse Rise And Fall Time
Pulse Width
Pulse Recurrence Frequency
(PRF)
Max. Peak Output Power
Max. Average Output Power
Positive Or Negative, Factory Configured
200 Volts
0 Volts
Controlled By Power Supply Input Voltage
50A Peak, 25A Average
(1)
<100ns (10% to 90%)
<200ns to 2ms, Controlled by Input Gate
Single shot to 50KHz, Controlled by Input Gate
10,000W
(2)
5,000W
(3)
Max. Duty Cycle
Droop (At 50A Output Current)
Over/undershoot
Jitter
Output Connector & Cable
INPUT DC VOLTAGE
Input Voltage Polarity
Maximum Value
Minimum Value
Maximum Input Power
Input DC Connector
50%
<5% @ 1ms pulse width, <10% @ 2ms pulse width
<5%
<10ns shot-to-shot
Type N, With 4 feet (~1.2M) 5
Coaxial Cable
Positive Or Negative (User-supplied)
(4)
200 Volts
0 Volts
5,000W
Type N, Rear Panel
GATE
Gate Source
Input Gate Connector
VOLTAGE & CURRENT MONITORS
Voltage Monitor
+5V ±1V into 50
BNC, Front Panel
50:1 into 50
, accuracy typically within 3% of the
actual output voltage
BNC, Front Panel
10A/V into 50
, accuracy typically within 3% of the
actual output current
BNC, Front Panel
Voltage Monitor Connector
Current Monitor
Current Monitor Connector
GENERAL
Support Power
Dimensions (Excluding Connec-
tors)
Weight (Approximate)
90VAC to 240VAC, 50/60Hz
19” W x 5.2” H x 16” D (48.25cm W x 13.2cm H x
41cm D)
18 lbs. (8.2 Kilograms)
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
200ns Minimum Pulse Width, 200V Output
(100ns/Div horizontal scale, 50V/Div vertical scale)
(25ns/Div horizontal scale, 50V/Div vertical scale)
Typical Output Waveform, 200V
(10μs/Div horizontal scale, 50V/Div vertical scale)
50KHz, 50% Duty Cycle, 200V Output
(8
Load, 10μs/Div horizontal scale, 50V/Div vertical scale)
(1)
When driving loads with impedances <5
, the output voltage must be limited to <200V,
so that the peak output current (V/R) does not exceed 50A, and the maximum
average
current (defined as I x Duty Cycle) does not exceed 25A.
Peak output power is defined as V x I during the output pulse.
Average output power is defined as V x I x Duty Cycle.
Input DC power supply must be the same polarity as the PVX-2110 (i.e. a positive output
PVX-2110 requires a positive high voltage DC input).
(2)
(3)
(4)