PS21A79
Intellimod Module
Dual-In-Line Intelligent Power Module
50 Amperes/600 Volts
Powerex, Inc., 173 Pavilion Lane,Youngwood, Pennsylvania 15697 (724) 925-7272
3
Rev. 08/09
Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Units
IGBT Inverter Sector
Collector-Emitter Saturation Voltage
VCE(sat)
IC = 50A, Tj = 25°C, VD = VDB = 15V, VIN = 5V
—
1.55
2.05
Volts
IC = 50A, Tj = 125°C, VD = VDB = 15V, VIN = 5V
—
1.65
2.10
Volts
Diode Forward Voltage
VEC
Tj = 25°C, -IC = 50A, VIN = 0V
—
1.70
2.20
Volts
Inductive Load Switching Times
ton
1.80
2.40
—
s
trr
VCC = 300V, VD = VDB = 15V,
—
0.30
—
s
tC(on)
IC = 50A, Tj = 125°C, VIN = 0 5V,
—
0.40
—
s
toff
Inductive Load (Upper-Lower Arm)
—
3.00
—
s
tC(off)
—
0.65
—
s
Collector-Emitter Cutoff Current
ICES
VCE = VCES, Tj = 25°C
—
1.0
mA
VCE = VCES, Tj = 125°C
—
10
mA
Control Sector
Circuit Current
ID
VD = VDB = 15V, VIN = 5V,
—
7.00
mA
Total of VP1-VPC, VN1-VNC
VD = VDB = 15V, VIN = 5V,
—
0.55
mA
VUFB-VUFS, VVFB-VVFS, VWFB-VWFS
VD = VDB = 15V, VIN = 0V,
—
7.00
mA
Total of VP1-VPC, VN1-VNC
VD = VDB = 15V, VIN = 0V,
—
0.55
mA
VUFB-VUFS, VVFB-VVFS, VWFB-VWFS
Fault Output Voltage
VFOH
VSC = 0V, FO Terminal Pull-up to 5V by 10k
4.9
—
Volts
VFOL
VSC = 1V, IFO = 1mA
—
0.95
Volts
Input Current
IIN
VIN = 5V
1.0
1.5
2.0
mA
Short-Circuit Trip Level*
ISC
-20°C ≤ TC ≤ 100°C, VD = 15V, RS = 21.5
85.0
—
150.0
Amps
Supply Circuit Undervoltage
UVDBt
Trip Level, TC ≤ 100°C
10.0
—
12.0
Volts
Protection
UVDBr
Reset Level, TC ≤ 100°C
10.5
—
12.5
Volts
UVDt
Trip Level, TC ≤ 100°C
10.3
—
12.5
Volts
UVDr
Reset Level, TC ≤ 100°C
10.8
—
13.0
Volts
Fault Output Pulse Width**
tFO
CFO = 22nF
1.0
1.8
—
ms
ON Threshold Voltage
Vth(on)
Applied between UP, VP, WP-VPC,
2.1
2.3
2.6
Volts
OFF Threshold Voltage
Vth(off)
UN, VN, WN-VNC
0.8
1.4
2.1
Volts
Temperature Output
VOT
At LVIC Temperature = 85°C
3.50
3.63
3.76
Volts
* Short-Circuit protection is functioning only at the lower arms. Please select the value of the external shunt resistor such that the SC trip level is less than 85A.
**Fault signal is asserted when the lower arm short circuit or control supply under-voltage protective functions operate. The fault output pulse-width tFO depends on the capacitance value
of CFO according to the following approximate equation: CFO = (12.2 x 10-6 x tFO [F]).
***When the temperature rises excessively, the controller (MCU) should stop the DIPIPM.