PS21869
Intellimod Module
Dual-In-Line Intelligent Power Module
50 Amperes/600 Volts
102
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
103
PS21869
Intellimod Module
Dual-In-Line Intelligent Power Module
50 Amperes/600 Volts
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Units
Control Sector
Supply Voltage
VD
Applied between VP1-VPC, VN1-VNC
13.5
15.0
16.5
Volts
VDB
Applied between VUFB-VUFS,
13.0
15.0
18.5
Volts
VVFB-VVFS, VWFB-VWFS
Circuit Current
ID
VD = VDB = 15V, VIN = 5V,
—
5.00
mA
Total of VP1-VPC, VN1-VNC
VD = VDB = 15V, VIN = 0V,
—
7.00
mA
Total of VP1-VPC, VN1-VNC
VD = VDB = 15V, VIN = 5V,
—
0.40
mA
VUFB-VUFS, VVFB-VVFS, VWFB-VWFS
VD = VDB = 15V, VIN = 0V,
—
0.55
mA
VUFB-VUFS, VVFB-VVFS, VWFB-VWFS
Fault Output Voltage
VFOH
VSC = 0V, FO Circuit: 10k Ω to 5V Pull-up
4.9
—
Volts
VFOL
VSC = 1V, IFO = 1mA
—
0.95
Volts
Input Current
IIN
VIN = 5V
1.00
1.50
2.00
mA
Short-Circuit Trip Level*
VSC(ref)
Tj = 25°C, VD = 15V
0.43
0.48
0.53
Volts
Supply Circuit Undervoltage
UVDBt
Trip Level, Tj ≤ 125°C
10.0
—
12.0
Volts
Protection
UVDBr
Reset Level, Tj ≤ 125°C
10.5
—
12.5
Volts
UVDt
Trip Level, Tj ≤ 125°C
10.3
—
12.5
Volts
UVDr
Reset Level, Tj ≤ 125°C
10.8
—
13.0
Volts
Fault Output Pulse Width**
tFO
CFO = 22nF
1.0
1.8
—
ms
ON Threshold Voltage
Vth(on)
Applied between UP, VP, WP-VPC,
2.1
2.3
2.6
Volts
OFF Threshold Voltage
Vth(off)
UN, VN, WN-VNC
0.8
1.4
2.1
Volts
Thermal Characteristics
Characteristic
Symbol
Condition
Min.
Typ.
Max.
Units
Junction to Fin
Rth(j-f)Q
IGBT Part (Per 1/6 Module)
—
1.42
°C/Watt
Thermal Resistance
Rth(j-f)D
FWDi Part (Per 1/6 Module)
—
2.00
°C/Watt
Recommended Conditions for Use
Characteristic
Symbol
Condition
Min.
Typ.
Max.
Units
Supply Voltage
VCC
Applied between P-N Terminals
0
300
400
Volts
Control Supply Voltage
VD
Applied between VP1-VPC, VN1-VNC
13.5
15.0
16.5
Volts
VDB
Applied between VUFB-VUFS,
13.0
15.0
18.5
Volts
VVFB-VVFS, VWFB-VWFS
Control Supply Variation
ΔVD, ΔVDB
-1
—
1
V/s
PWM Input Frequency
fPWM
Tf ≤ 100°C, Tj ≤ 125°C
—
20
kHz
* Short-Circuit protection is functioning only at the lower arms. Please select the value of the external shunt resistor such that the SC trip level is less than 85A.
**Fault signal is asserted when the lower arm short circuit or control supply under-voltage protective functions operate. The fault output pulse-width tFO depends on the capacitance value
of CFO according to the following approximate equation: CFO = (12.2 x 10-6) x tFO {F} .