110
P
Note 1: Model name, Input voltage range, Nominal output voltage, Maximum output current
and country of manufacture are shown here.
Note 2: Input & output terminal
4-2
6-0.6
PR
-SERIES
Rectifier module 500W
m
Features
v
marking (Low Voltage Directive)
v
Rectifier module
AC filtering module used in AC front end of DC-DC module.
Connect external filtering capacitor to output.
v
Input 100V/200VAC
v
Output voltage detecting signal (power-on signal)
v
Power failure alarm signal during instant input
v
Wide baseplate temperature: –
20 ~
+
85
°C
Conduction cooling
v
2 year warranty
(Low Voltage Directive)
V
: Safety standard approved
m
Model name
PR 500-280
Name of series
Nominal output
power
Nominal output
voltage
0
1. Input voltage range
0
2.
Rated output voltage
0
3.
Max. output current/powe
r
0
4. Efficiency (typ)
0
5. Input alarm signal
0
6. Power on signal
0
7. Auxiliary power
0
8. Cooling
0
9. Operating ambient
temperature
10. Withstand voltage
11. Safety standard
85 ~ 132VAC/170 ~ 265VAC (47 ~ 440Hz) selectable
280VDC (230 ~ 370VDC)
85 ~ 132VAC: 2.1A 500W, 170 ~ 265VAC: 3.15A 750W
95%: 200VAC at full load
Detection signal output when input 10mS or more is interrupted (ACF terminal)
Signal output while output voltage is supplied (ENA terminal)
Connect to control terminal of DC-DC converter module
Auxiliary power output for external signal (AUX terminal: DC16 ~ 20V 10mA max.)
Conduction cooling (Heatsink & airflow has to be chosen according to instruction manual)
Baseplate temperature: –20 ~ +85°C (output derating is different according to condition)
Ambient temperature: above –20°C
Input/output terminal to baseplate: 3.0kVAC for 1 min.
Approved by UL1950 , CSA950(C-UL) and EN60950(BSI)
m
Specifications
85 ~ 132VAC
170 ~ 265VAC
8.8A (input at 100VAC)
6.6A (input at 200VAC)
PR500-280
2.10A
(output at 240VDC)
3.15A
(output at 240VDC)
500W
750W
V
V
V
V
V
V
Model
Input current (typ)
Max.
output current
UL
CSA
EN
m
Product lineup
280VDC
(230 ~ 370VDC)
m
Outline drawings
m
Block diagram
[Input 100VAC]
[Input 200VAC]
For 100/200V input selection, connect
center mode of C1 and C2 to AC(N) of
PR500 connector.
(C1, C2: cap for voltage doubler rectifier
and filtering capacitor)
(Unit: mm)
Multigrades : 2 year warranty
Input voltage
range
Nominal output
voltage
Max. output
power
v
Request customer specification for further details of specifications, outline, characteristics, etc.
Read the instruction manual before usage.
v
Contact us about delivery before ordering.
R (in-rush current limiting resistor)
R (in-rush current limiting resistor)