Input:
Output:
Current:
Package:
35-75V
12V
17A (200W)
Quarter-brick
Product # PQ60120QEA17
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005068 Rev. B
06/03/09
Page 2
Technical Specification
0.300
(7.62)
0.600
(15.24)
0.43
(10.9)
0.150
(3.81)
0.300
(7.62)
0.450
(11.43)
0.600
(15.24)
0.14
(3.6)
Top View
Side View
Mechanical Diagram (open frame)
Bottom side
Clearance
See Note 9
NOTES
1)Pins 1-3, 5-7 are 0.040” (1.02mm) diameter with
0.080” (2.03 mm) diameter standoff shoulders.
2)Pins 4 and 8 are 0.062” (1.57 mm) diameter with 0.100”
(2.54 mm) diameter standoff shoulders.
3)Other pin extension lengths available. Recommended pin
length is 0.03” (0.76mm) greater than the PCB thickness.
4)All Pins: Material - Copper Alloy
Finish (RoHS 5/6) - Tin/Lead over Nickel plate
Finish (RoHS 6/6) - Matte Tin over Nickel plate
5)Undimensioned components are shown for visual reference only.
6)All dimensions in inches (mm)
Tolerances:
x.xx +0.02 in. (x.x +0.5mm)
x.xxx +0.010 in. (x.xx +0.25mm)
7)Weight: 1.5 oz. (42 g) typical
8)Workmanship: Meets or exceeds IPC-A-610C Class II
9)UL/TUV standards require a clearance greater than 0.04” (1.02mm) between input and
output for basic insulation. This issue should be considered if any copper traces are on
the top side of the user’s board. Note that the ferrite cores are considered part of the
input/primary circuit.
10)The flanged pins are designed to permit surface mount soldering (allowing to avoid the
wave soldering process) through the use of the flanged pin-in-paste technique.
2.30
(58.4)
2.00
(50.8)
0.025 +0.024
(0.64 +0.61)
Lowest
Component
Load Board
Flanged Pin
See Note 10
0.180
(4.57)
See Note 3
0.436 max
(11.06)
1.45
(36.8)
PIN DESIGNATIONS
PIN NAME
FUNCTION
1
Vin(+)
Positive input voltage
2
ON/OFF
TTL input to turn
converter on and off,
referenced to Vin(–),
with internal pull up.
3
Vin(–)
Negative input voltage
4
Vout(–)
Negative output voltage
5
SENSE(–) Negative remote sense1
6
TRIM
Output voltage trim2
7
SENSE(+) Positive remote sense3
8
Vout(+)
Positive remote sense3
Notes:
1.
SENSE(–) should be connected to Vout(–)
either remotely or at the converter.
2.
Leave TRIM pin open for nominal output
voltage.
3.
SENSE(+) should be connected to
Vout(+) either remotely or at the
converter.