3
PM52AUBW060
Intellimod Module
Active Filter IPM
20 Amperes/600 Volts
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Electrical Characteristics, Tj = 25 °C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Units
Output Voltage Adjust (1)
VO
Vi = 100V, LR = 400, Vsig = 1.38V
353
360
367
Volts
Output Voltage Adjust (2)
VO
Vi = 100V, LR = 400, Vsig = 2.08V
293
300
307
Volts
Output Voltage Adjust (3)
VO
Vi = 100V, LR = 400, Vsig = 3.26V
193
200
207
Volts
Output Voltage Stability vs Input Voltage
VO = 300V, LR = 400
(1-1)
-1
–
+1
%
(1-2)
-1
–
+1
%
Output Voltage Stability vs Load
Vi = 100V, VO = 300V
(2)
0
–
+6
%
Output Voltage Stability vs Ambient Temperature
Vi = 100V, VO = 300V, LR = 400
(3-1)
-3
–
0%
(3-2)
0
–
+3
%
Rise Time
Vi = 100V, VO = 300V, LR = 48
––
100
ms
Over Shoot Voltage
Vi = 100V, VO = 300V,
––
30
Volts
LR = 400
, L1 = 1mH
Power Factor
cos
Φ
Vi = 100V, VO = 300V, LR = 400
0.99
0.995
1.0
VO(Vi = 90V) – VO(Vi = 100V)
x 100%
VO(Vi = 100V)
VO(Vi = 110V) – VO(Vi = 100V)
x 100%
VO(Vi = 100V)
VO(Load = 400) – VO(Load = 48)
x 100%
VO(Load = 48)
VO(Ta = -20°C) – VO(Ta = +25°C)
x 100%
VO(Ta = +25°C)
VO(Ta = +100°C) – VO(Ta = +25°C)
x 100%
VO(Ta = +25°C)
OT
Multiplx
S
R
L
Control Circuit
Rv
N.C.
GND
On/
Off
FO
VD
VD = 15V
VSIG
VCTRL
Vo
P2
N2
Load
–
+
CO C
O
VAOUT
10
F
Pl
Nl
Ll
DB1
Ci
Vi
Noise
Filter
Input
Current
Negative
Feedback
Output
O/V
Protection
Drive
Circuit
Comparator
Oscillator
Buffer
for
VCTRL
Open Collector
Output
Voltage
Negative
Feedback
Control
Power Supply
UV Protection
Fault
Out
IGBT OC
Protection
Internal Function Block Diagram
Note 1:
When applying 200V class input voltage,
please use In-rush current limitter S and R
for stable and safe operation.
Note 2:
Selection of Rv:
When applying 200V class Input Voltage,
please use 270k
, 0.25W.
When applying 100V input voltage please
use Rv = 0 (short).
Note 3:
Please make sure to short between VO and