Technical Specifications continued
Designed and built in the U.K. by:
82100-0046
Thurlby Thandar Instruments Ltd
.
Glebe Road, Huntingdon. Cambs. PE18 7DX England
Tel: 01480 412451
Fax: 01480 450409 e-mail: sales@ttinst.co.uk
Thurlby Thandar Instruments Ltd. operates a policy of continuous development and
reserves the right to alter specifications without prior notice.
LOGIC OUTPUT - PL330QMT & PL330TP
Output Voltage
Range:
4 to 6 Volts
Output Current:
0.1 to 7 Amps.
Output Switch:
Isolates the output and permits output voltage to be set bef-
ore connecting the load.
Output Terminals:
4mm terminals on 19mm (0.75") spacing.
Over-Voltage
Protection:
Above 7 Volts
Output Protection:
Clamped by the over-voltage protection circuit for forward
voltages over 7 Volts and up to 1 Amp forward current. Di-
ode clamped for reverse voltages and up to 3 Amps reverse
current.
Load Regulation:
<0.01% of maximum output for 90% load change
Line Regulation:
<0.01% of maximum output for 10% line voltage change
Remote Sense:
Eliminates up to 0.5V drop per lead.
Ripple and Noise:
Typically <1mV rms
Transient Response: <20usec to within 50mV of setting for 90% load change
Temperature
Coefficient:
Typically <100ppm/
oC
Meter Type:
3.75 digit (4095 count) with 12.5mm (0.5") LEDs. Reading
rate 4 per second.
Meter Resolution:
Voltage: 10mV
Current: 10mA
Meter Accuracy:
Voltage:
±
(0.2% of reading + 1 digit )
Current:
±
(0.5% of reading + 1 digit )
PL-P MODELS,ADDITIONAL SPECIFICATIONS
Remote programmable versions in the range feature full control, read back and
status reporting via the GPIB and RS232 interfaces. The GPIB interface con-
forms to the IEEE 488.1 and 488.2 standards and the RS232 interface is fully
compatible with the Thurlby-Thandar Addressable RS232 Chain (ARC) standard.
8 rear panel DIP switches are used to specify baud rate, bus address and active
interface (GPIB or RS232). Remote/Local operation is selected by a front panel
switch.
LOCAL OPERATION
For a programmable instrument operated in local state, all capabilities and speci-
fications remain unchanged from those of a standard instrument .
REMOTE OPERATION
With the instrument switched to the remote state, all voltage and current adjust-
ment controls become inoperative and commands received over the active inter-
face will be parsed and executed.
MAIN OUTPUT(S) - REMOTE OPERATION
Output Voltage
Setting:
12 bit resolution (10mV steps)
Output Current
Setting:
12 bit resolution (1mA steps)
Setting Accuracy:
Voltage:
±
(0.1% + 10mV)
Current:
±
(0.2% + 2mA)
Output Switch:
Electronic by interface command (front panel output
switches must be set to ON)
Readback Resolution:Voltage: 10mV over the entire range
Current: 1mA over the entire range
Readback Accuracy: Voltage:
±
(0.1% of reading + 1 digit)
Current:
±
(0.3% of reading + 1 digit)
Current Meter
Damping:
commands
Nominally 20ms switchable to 2 sec and back by remote
LOGIC OUTPUT (PL330TP) - REMOTE OPERATION
Output Voltage
Range:
4 to 6 Volts in 10mV steps
Output Current:
1 to 7 Amps in approximate 1A steps
Setting Accuracy:
Voltage:
±
(0.2% + 10mV)
Output Switch:
Electronic by interface command (front panel output switch
must be set to ON)
Readback Resolution:Current: 10mA
Readback Accuracy: Current:
±
(0.5% of reading + 1 digit )
REMOTE CONTROL INTERFACES - PL-P MODELS
Both interfaces feature full control, readback and status reporting.
RS232:
Variable Baud rate (9600 maximum), 9 pin D-connector (fe-
male). Fully compatible with ARC (Addressable RS232
Chain) system.
GPIB:
Conforming with IEEE-488.1 and IEEE-488.2
Address Selection:
By rear panel DIP switch.
Remote/Local
Operation:
Selected by front panel switch.
Remote Command Response Time:
Interface:
<15ms(singlecommand,inputbufferempty).
Output Voltage - Up:Time constant typically 2ms, e.g. 10ms to settle within 1%
of a step change, 15ms to settle within 0.1%.
OutputVoltage-DoTime constant determined by the discharge of the power
supply output capacitor (47uF). Typically <10ms to settle
within 1% for a 10V step change at 50mA load current; typi-
cally <200ms to settle within 1% at zero load.
Output Current:
Typically 50ms to settle within 10mA for a 1A change.
GENERAL
Power Requirements:
Input Voltage:
Input Voltage Range:
Power Consumption:
Internally set for 110, 120, 220 or 240VAC 50/60Hz
±
10% of voltage setting
Single
Dual
30V/1A
75VA
15V/4A & 30V/2A150VA 300VA 450VA
30V/3A
225VA 450VA 600VA
Operating Range: 5
oC to 40oC, 20% to 80% RH
Storage Range: -20
oC to +60oC
Single
30V/1A PL
4.0kg
15V/4A PL
5.0kg
30V/2A PL
5.0kg
30V/3A PL
6.0kg
30V/3A PL-P
6.5kg
Triple
150VA 300VA
Environmental:
Weight:
Dual
8.0kg
Triple
11.5kg
9.5kg
12.0kg 15.5kg
12.5kg 16.0kg
13.5kg
Size:
PL310, PL154, &
PL320:
PL330:
PL330P:
PL310QMD, PL310QMT, &
PL320QMD:
PL330QMD, &
PL330DP:
PL320QMT:
PL330QMT, &
PL330TP:
Rack Mount Option:
155mm(W) x 170mm(H) x 265mm(D)
155mm(W) x 170mm(H) x 300mm(D)
207mm(W) x 170mm(H) x 300mm(D)
350mm(W) x 170mm(H) x 265mm(D)
350mm(W) x 170mm(H) x 300mm(D)
425mm(W) x 170mm(H) x 265mm(D)
425mm(W) x 170mm(H) x 300mm(D)
19 inch 4U mount for two PL330P or one PL330DP/TP.
Anti-tamper cover for security.
Designed and manufactured to comply with IEC 348 and
IEC1010-1. Full safety sockets available to special order.
Designed and manufactured to comply with EN50081–1
and EN50082–1.
Electrical Safety:
EMC: