2.5 V, 25 A / 62.5W Electrical Specification
PKM 4619E PI
Tref = -40 to +90C, VI = 36 to 75 V, sense pins connected to output pins unless otherwise specified under Conditions.
Typical values given at: Tref = +25°C, VI= 53 V, max IO , unless otherwise specified under Conditions.
Characteristics
Conditions
min
typ
max
Unit
VI
Input voltage range
36
75
V
VIoff
Turn-off input voltage
Decreasing input voltage
28
31
33
V
VIon
Turn-on input voltage
Increasing input voltage
32
34
36
V
CI
Internal input capacitance
1
F
PO
Output power
0
62.5
W
SVR
Supply voltage rejection (ac)
f = 100 Hz sinewave, 1 Vp-p
70
dB
50 % of max IO
90
max IO
88
50 % of max IO , VI = 48 V
90
η
Efficiency
max IO , VI = 48 V
88
%
Pd
Power Dissipation
max IO
8.6
12
W
Pli
Input idling power
IO = 0 A, VI = 53 V
1.3
W
PRC
Input standby power
VI = 53 V (turned off with RC)
0.1
W
fs
Switching frequency
0-100 % of max IO
175
kHz
VOi
Output voltage initial setting and
accuracy
Tref = +25°C, VI = 53 V, IO = 25 A
2.45
2.50
2.55
V
Output adjust range
See operating information
2.25
2.75
V
Output voltage tolerance band
10-100% of max IO
2.42
2.58
V
Idling voltage
IO = 0 A
2.42
2.58
V
Line regulation
max IO
0
10
mV
VO
Load regulation
VI = 53 V, 1-100% of max IO
2
10
mV
Vtr
Load transient
voltage deviation
±350
mV
ttr
Load transient recovery time
VI = 53 V, Load step 25-75-25 % of
max IO, di/dt = 0.5 A/s,
see Note 1
50
s
tr
Ramp-up time
(from 1090 % of VOi)
6
10
ms
ts
Start-up time
(from VI connection to 90% of VOi)
10-100% of max IO,
Tref = 25C, VI = 53 V
8
15
ms
max IO
0.1
ms
tf
Vin shutdown fall time
(from VI off to 10% of VO)
IO = 0 A
20
s
RC start-up time
max IO
8
ms
max IO
0.1
ms
tRC
RC shutdown fall time
(from RC off to 10% of VO)
IO = 0 A
20
s
IO
Output current
0
25
A
Ilim
Current limit threshold
VO = 2.4V, Tref < max Tref
26
29
34
A
Isc
Short circuit current
Tref = 25C, VO < 0.2V
34
38
A
VOac
Output ripple & noise
See ripple & noise section,
max IO, VOi
40
100
mVp-p
OVP
Over voltage protection
Tref = +25°C, VI = 53 V, 10-100% of
max IO
3.5
5.0
V
Note 1: Output filter according to Ripple & Noise section
E