6.0 V/20 A Electrical Specification
PKM 4117VD PINB
Tref = -40 to +90C, VI = 36 to 75 V, sense pins connected to output pins unless otherwise specified under Conditions.
Typical values given at: Tref = +25°C, VI= 53 VI max IO, unless otherwise specified under Conditions.
Characteristics
Conditions
min
typ
max
Unit
VI
Input voltage range
36
75
V
VIoff
Turn-off input voltage
Decreasing input voltage
30
31.4
33
V
VIon
Turn-on input voltage
Increasing input voltage
33
33.9
35
V
CI
Internal input capacitance
4.3
F
PO
Output power
Output voltage initial setting
0
120
W
50 % of max IO
91.5
max IO
92.0
50 % of max IO, VI = 48 V
91.8
η
Efficiency
max IO, VI = 48 V
92.1
%
Pd
Power Dissipation
max IO
10.4
W
Pli
Input idling power
IO = 0 A, VI = 53 V
3.7
W
PRC
Input standby power
VI = 53 V (turned off with RC)
W
fs
Switching frequency
0-100 % of max IO
180
200
220
kHz
VOi
Output voltage initial setting and
accuracy
Tref = +25°C, VI = 53 V, IO = 20 A
5.88
6.00
6.12
V
Output adjust range
See operating information
5.40
V
Output voltage tolerance band
10-100 % of max IO
5.76
6.24
V
Idling voltage
IO = 0 A
5.76
6.24
V
Line regulation
max IO
2.6
15
mV
VO
Load regulation
VI = 53 V, 0-100 % of max IO
3.3
15
mV
Vtr
Load transient
voltage deviation
±500
mV
ttr
Load transient recovery time
VI = 53 V, Load step 25-75-25 % of
max IO, di/dt = 1 A/s
139
s
tr
Ramp-up time
(from 1090 % of VOi)
6
30
ms
ts
Start-up time
(from VI connection to 90 % of VOi)
10-100 % of max IO
8
50
ms
max IO
200
ms
tf
VI shut-down fall time
(from VI off to 10 % of VO)
IO = 0 A
12
s
RC start-up time
max IO
8
ms
max IO
255
ms
tRC
RC shut-down fall time
(from RC off to 10 % of VO)
IO = 0 A
12
s
IO
Output current
0
20
A
Ilim
Current limit threshold
Tref < max Tref
30
A
Isc
Short circuit current
Tref = 25C
40
A
VOac
Output ripple & noise
See ripple & noise section,
max IO, VOi
45
mVp-p
OVP
Over voltage protection
Tref = +25°C, VI = 53 V, 0-100 % of
max IO
7.30
V
E
PKM 4000D PINB Series
DC/DC converters, Input 36-75 V, Output 40 A/132 W
EN/LZT 146 306 R4A July 2008
Ericsson Power Modules AB
Technical Specification
14