參數(shù)資料
型號: PIC16F636-E/P
廠商: Microchip Technology
文件頁數(shù): 34/74頁
文件大?。?/td> 0K
描述: IC MCU FLASH 2KX14 14DIP
產(chǎn)品培訓(xùn)模塊: Asynchronous Stimulus
標(biāo)準(zhǔn)包裝: 30
系列: PIC® 16F
核心處理器: PIC
芯體尺寸: 8-位
速度: 20MHz
外圍設(shè)備: 欠壓檢測/復(fù)位,LVD,POR,WDT
輸入/輸出數(shù): 11
程序存儲器容量: 3.5KB(2K x 14)
程序存儲器類型: 閃存
RAM 容量: 128 x 8
電壓 - 電源 (Vcc/Vdd): 2 V ~ 5.5 V
振蕩器型: 內(nèi)部
工作溫度: -40°C ~ 125°C
封裝/外殼: 14-DIP(0.300",7.62mm)
包裝: 管件
配用: AC164039-ND - MODULE SKT PROMATE II 20DIP/SOIC
AC162057-ND - MPLAB ICD 2 HEADER 14DIP
ACICE0207-ND - MPLABICE 14P 300 MIL ADAPTER
Micrel, Inc.
KSZ8841-PMQL
October 2007
4
M9999-100407-1.5
Contents
Pin Configuration .............................................................................................................................................................. 8
Pin Description .................................................................................................................................................................. 9
Functional Description ................................................................................................................................................... 14
PCI Bus Interface Unit .................................................................................................................................................. 14
PCI Bus Interface ................................................................................................................................................. 14
TXDMA Logic and TX Buffer Manager ................................................................................................................ 14
RXDMA Logic and RX Buffer Manager................................................................................................................ 14
Power Management...................................................................................................................................................... 14
Power down.......................................................................................................................................................... 14
Wake-on-LAN....................................................................................................................................................... 14
Link Change ......................................................................................................................................................... 15
Wake-up Packet ................................................................................................................................................... 15
Magic Packet........................................................................................................................................................ 15
Physical Layer Transceiver (PHY) ................................................................................................................................. 16
100BASE-TX Transmit.................................................................................................................................................. 16
100BASE-TX Receive................................................................................................................................................... 16
PLL Clock Synthesizer (Recovery) ............................................................................................................................... 16
Scrambler/De-scrambler (100BASE-TX Only).............................................................................................................. 16
10BASE-T Transmit ...................................................................................................................................................... 16
10BASE-T Receive ....................................................................................................................................................... 16
MDI/MDI-X Auto Crossover .......................................................................................................................................... 17
Straight Cable....................................................................................................................................................... 17
Crossover Cable................................................................................................................................................... 18
Auto Negotiation ........................................................................................................................................................... 18
LinkMD Cable Diagnostics ............................................................................................................................................. 20
Access........................................................................................................................................................................... 20
Usage............................................................................................................................................................................ 20
Media Access Control (MAC) and other........................................................................................................................ 20
Inter Packet Gap (IPG) ................................................................................................................................................. 20
Back-Off Algorithm........................................................................................................................................................ 20
Late Collision ................................................................................................................................................................ 20
Flow Control.................................................................................................................................................................. 20
Half-Duplex Backpressure ............................................................................................................................................ 21
Clock Generator............................................................................................................................................................ 21
EEPROM Interface ....................................................................................................................................................... 21
Loopback Support......................................................................................................................................................... 23
Host Communication ...................................................................................................................................................... 24
Host Communication Descriptor Lists and Data Buffers .............................................................................................. 24
Receive Descriptors (RDES0-RDES3) ......................................................................................................................... 24
Transmit Descriptors (TDES0-TDES3)......................................................................................................................... 26
PCI Configuration Registers .......................................................................................................................................... 28
Configuration ID Register (CFID Offset 00H) ............................................................................................................... 29
Command and Status Configuration Register (CFCS Offset 04H)............................................................................... 29
Configuration Revision Register (CFRV Offset 08H).................................................................................................... 31
Configuration Latency Timer Register (CFLT Offset 0CH)........................................................................................... 31
Configuration Base Memory Address Register (CBMA Offset 10H) ............................................................................ 31
Subsystem ID Register (CSID Offset 2CH) .................................................................................................................. 32
Capabilities Pointer Register (CCAP Offset 34H)......................................................................................................... 32
Configuration Interrupt Register (CFIT Offset 3CH) ..................................................................................................... 32
Capabilities ID Register (CCID Offset 50H).................................................................................................................. 33
Power-Management Control and Status Register (CPMC Offset 54H)........................................................................ 35
PCI Control & Status Registers ..................................................................................................................................... 36
MAC DMA Transmit Control Register (MDTXC Offset 0x0000) ................................................................................... 36
MAC DMA Receive Control Register (MDRXC Offset 0x0004).................................................................................... 37
相關(guān)PDF資料
PDF描述
GRM2165C1H6R2CD01J CAP CER 6.2PF 50V NP0 0805
GRM2165C1H6R2CD01D CAP CER 6.2PF 50V NP0 0805
GRM2165C1H5R6CD01J CAP CER 5.6PF 50V NP0 0805
GRM2165C1H5R6CD01D CAP CER 5.6PF 50V NP0 0805
VI-B6K-IW-F1 CONVERTER MOD DC/DC 40V 100W
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
PIC16F636-I/ML 功能描述:8位微控制器 -MCU 4 KB 128 RAM 12I/O RoHS:否 制造商:Silicon Labs 核心:8051 處理器系列:C8051F39x 數(shù)據(jù)總線寬度:8 bit 最大時鐘頻率:50 MHz 程序存儲器大小:16 KB 數(shù)據(jù) RAM 大小:1 KB 片上 ADC:Yes 工作電源電壓:1.8 V to 3.6 V 工作溫度范圍:- 40 C to + 105 C 封裝 / 箱體:QFN-20 安裝風(fēng)格:SMD/SMT
PIC16F636-I/P 功能描述:8位微控制器 -MCU 4kb 128 RAM 12 I/O RoHS:否 制造商:Silicon Labs 核心:8051 處理器系列:C8051F39x 數(shù)據(jù)總線寬度:8 bit 最大時鐘頻率:50 MHz 程序存儲器大小:16 KB 數(shù)據(jù) RAM 大小:1 KB 片上 ADC:Yes 工作電源電壓:1.8 V to 3.6 V 工作溫度范圍:- 40 C to + 105 C 封裝 / 箱體:QFN-20 安裝風(fēng)格:SMD/SMT
PIC16F636-I/P 制造商:Microchip Technology Inc 功能描述:IC 8BIT FLASH MCU 16F636 DIP14
PIC16F636-I/SL 功能描述:8位微控制器 -MCU 4kb 128 RAM 12 I/O RoHS:否 制造商:Silicon Labs 核心:8051 處理器系列:C8051F39x 數(shù)據(jù)總線寬度:8 bit 最大時鐘頻率:50 MHz 程序存儲器大小:16 KB 數(shù)據(jù) RAM 大小:1 KB 片上 ADC:Yes 工作電源電壓:1.8 V to 3.6 V 工作溫度范圍:- 40 C to + 105 C 封裝 / 箱體:QFN-20 安裝風(fēng)格:SMD/SMT
PIC16F636-I/SL 制造商:Microchip Technology Inc 功能描述:8BIT FLASH MCU SMD 16F636 SOIC14