PI74FCT16244T/162244T
16-Bit Buffer/Line Drivers
3
PS2031N
11/06/08
DC Electrical Characteristics (Over the Operating Range, TA = –40°C to +85°C, VCC = 5.0V ±10%)
Parameters
Description
Test Conditions(1)
Min.
Typ.(2)
Max.
Units
VIH
Input HIGH Voltage
Guaranteed Logic HIGH Level
2.0
V
VIL
Input LOW Voltage
Guaranteed Logic LOW Level
0.8
V
IIH
Input HIGH Current
Standard Input, VCC = Max.
VIN= VCC
1
μA
IIH
Input HIGH Current
Standard I/O, VCC = Max.
VIN= VCC
1
μA
IIL
Input LOW Current
Standard Input , VCC = Min.
VIN=GND
–1
μA
IIL
Input LOW Current
Standard I/O, VCC = Min.
VIN=GND
–1
μA
IOZH
High Impedance
VCC=Max.
VOUT=2.7V
1
μA
IOZL
Output Current
VCC=Max.
VOUT=0.5V
–1
μA
VIK
Clamp Diode Voltage
VCC = Min., IIN = –18mA
–0.7
–1.2
V
IOS
Short Circuit Current
VCC = Max.(3),VOUT = GND
–80
–140
–320
mA
IO
Output Drive Current
VCC = Max.(3),VOUT= 2.5V
–50
–180
mA
VH
Input Hysteresis
100
mV
Storage Temperature ........................................................ –65°C to +150°C
Ambient Temperature with Power Applied ......................... –40°C to +85°C
Supply Voltage to Ground Potential (Inputs & Vcc Only) ...–0.5V to +7.0V
Supply Voltage to Ground Potential (Outputs & D/O Only) –0.5V to +7.0V
DC Input Voltage ................................................................–0.5V to +7.0V
DC Output Current .......................................................................... 120mA
Power Dissipation ............................................................................... 1.0W
Note:
Stresses greater than those listed under MAXIMUM
RATINGS may cause permanent damage to the
device. This is a stress rating only and functional
operation of the device at these or any other conditions
above those indicated in the operational sections of this
specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may
affect reliability.
Notes:
1. For Max. or Min. conditions, use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at Vcc = 5.0V, +25°C ambient and maximum loading.
3. Not more than one output should be shorted at one time. Duration of the test should not exceed one second.
Maximum Ratings
(Above which the useful life may be impaired. For user guidelines, not tested.)
08-0291