PI74FCT16245T
PI74FCT162245T
Fast CMOS 16-Bit Bidirectional Tranceivers
3
PS2032K
11/06/08
Notes:
1.
For Max. or Min. conditions, use appropriate value specied under Electrical Characteristics for the applicable device type.
2.
Typical values are at VCC = 5.0V, +25°C ambient and maximum loading.
3.
Not more than one output should be shorted at one time. Duration of the test should not exceed one second.
DC Electrical Characteristics (Over the Operating Range, TA = –40°C to +85°C, VCC = 5.0V ±10%)
Param-
eters
Description
Test Conditions(1)
Min.
Typ.(2)
Max.
Units
VIH
Input HIGH Voltage
Guaranteed Logic HIGH Level
2.0
V
VIL
Input LOW Voltage
Guaranteed Logic LOW Level
0.8
IIH
Input HIGH Current
Standard Input, VCC = Max.
VIN = VCC
1
μA
Standard I/O, VCC = Max.
VIN = VCC
1
IIL
Input LOW Current
Standard Input, VCC = Min.
VIN = GND
–1
Standard I/O, VCC = Min.
VIN = GND
–1
IOZH
High Impedance
VCC = Max.
VOUT = 2.7V
1
IOZL
Output Current
VCC = Max.
VOUT = 0.5V
–1
VIK
Clamp Diode Voltage
VCC = Min., IIN = –18mA
–0.7
–1.2
V
IOS
Short Circuit Current
VCC = Max.(3), VOUT = GND
–80
–140
–300
mA
IO
Output Drive Current
VCC = Max.(3), VOUT = 2.5V
–50
–180
VH
Input Hysteresis
100
mV
PI74FCT16245T Output Drive Characteristics (Over the Operating Range)
Parameters
Description
Test Conditions(1)
Min.
Typ.(2)
Max.
Units
VOH
Output HIGH Voltage
VCC = Min., VIN = VIH or VIL
IOH = –3.0mA
2.5
3.5
V
IOH = –15.0mA
2.4
3.5
IOH = –32.0mA
VOL
Output LOW Voltage
VCC = Min., VIN = VIH or VIL IOL = 64mA
0.2
0.55
IOFF
Power Down Disable
VCC = 0V, VIN or VOUT ≤ 4.5V
±100
μA
PI74FCT162245T Output Drive Characteristics (Over the Operating Range)
Parameters
Description
Test Conditions(1)
Min.
Typ.(2)
Max.
Units
VOH
Output HIGH Voltage
VCC = Min., VIN = VIH or VIL
IOH = –24.0mA
2.4
3.3
V
VOL
Output LOW Voltage
VCC = Min., VIN = VIH or VIL
IOL = 24mA
0.3
0.55
IODL
Output LOW Current
VCC = 5V, VIN = VIH or VIL, VOUT = 1.5V(3)
60
115
160
mA
IODH
Output HIGH Current
VCC = 5V, VIN = VIH or VIL, VOUT = 1.5V(3)
–60
–115
–150
Notes:
1.
For Max. or Min. conditions, use appropriate value specied under Electrical Characteristics for the applicable device type.
2.
Typical values are at VCC = 5.0V, +25°C ambient and maximum loading.
3.
Not more than one output should be shorted at one time. Duration of the test should not exceed one second.
Notes:
1.
For Max. or Min. conditions, use appropriate value specied under Electrical Characteristics for the applicable device type.
2.
Typical values are at VCC = 5.0V, +25°C ambient and maximum loading.
08-0291