![](http://datasheet.mmic.net.cn/260000/PFC375-4002F_datasheet_15937150/PFC375-4002F_3.png)
3
PerFormanCe POWER PFC375
OUTPUT SPECIFICATIONS
PARAMETER
Efficiency
Minimum Loads
CONDITIONS/DESCRIPTION
Full rated load, 110 VAC. Varies with distribution of loads among outputs.
Single output models.
Multiple output models, 5V main output only.
Multiple output models, 24V main output only.
Full load, 20MHz bandwidth.
300 LFM forced air cooling required for operation. See optional fan.
Continuous power, multiple output models.
Peak power, all models.
Output voltage overshoot/undershoot at turn-on.
Varies by output. Total regulation includes: line changes from 85-132 VAC or
170-264 VAC, changes in load starting at 20% load and changing to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100% load change,
3% max. deviation. (Main output only on multi-output units).
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
MIN
68
0
3.5
1
See Model Selection Charts
NOM
MAX
UNITS
%
Amps
Ripple and Noise
Output Power
375
Watts
450
0
Overshoot / Undershoot
Regulation
V
See Model Selection Charts
Transient Response
1
mS
Turn-On Delay
Turn-On Rise Time
1
Sec
mS
10
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER
Overvoltage Protection
CONDITIONS/DESCRIPTION
Provided on single output units and the main output only of multiple output units.
PFC375-30XX, PFC375-40XX, PFC375-45XX
MIN
NOM
MAX
UNITS
6.0
13.5
17.0
27.0
30.8
60.0
27.0
6.4
15.5
19.5
30.7
35.0
70.0
30.7
PFC375-1012
PFC375-1015
PFC375-1024
PFC375-1028
PFC375-1048
PFC375-42XX
V
Overload Protection
Overtemperature Protection
Remote Sense
Current Share
Inhibit
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
System shutdown due to excessive internal temperature, automatic reset.
Total voltage compensation for cable losses with respect to the main output.
Accuracy of shared current with up to 6 parallel units.
TTL compatible logic signal will inhibit outputs by the application of a logic low signal.
An open circuit or external TTL high signal allows normal operation.
TTL compatible logic signal. Time before regulation dropout due to
loss of input power at 110 VAC.
TTL compatible signal. Signal is low if main output is greater or less than 10% of nominal.
Provides 170mA current to user supplied fan if fan option is not selected.
250
10
mV
%
Input Power
Fail Warning
Power Good
Fan Voltage
5
mS
12
V
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
Agency Approvals
CONDITIONS/DESCRIPTION
UL1950.
CSA 22.2 NO. 234/950.
EN60950 (TüV).
Input to output.
FCC CFR title 47 Part 15 Sub-Part B - Conducted.
EN55022 / CISPR 22 Conducted.
Per EN61000-4-2, level 4.
Per EN61000-4-3, level 3.
Per EN61000-4-4, level 4.
Per EN61000-4-5 class 3.
MIN
NOM
MAX
UNITS
Approved
Dielectric Withstand Voltage
Electromagnetic Interference
2600
B
B
8
10
±4
1
2
VDC
Class
ESD Susceptibility
Radiated Susceptibility
EFT/Burst
Input Transient Protection
kV
V/M
kV
Line to Line
Line to Ground
kV
Insulation Resistance
Leakage Current
Input to output.
Per EN60950, 264 VAC.
10
M
mA
2.0