1
Powering Communications and Technology
40
45
50
55
60
65
70
75
80
85
90
95
1
2
3
4
5
6
7
8
9
10
X10 = LOAD %
E
OES021ZC-A
OES025ZD-A
OES033ZE-A
OES040ZG-A
FEATURES
OES SERIES
40 WATT
OES DC/DC converters are ultra-dense, 40
Watt, single output converters produced for the
telecom and networking markets. Making use of
open-frame packaging, planar magnetics, high
efficiency topologies, and surface-mount design,
the OES has superior thermal performance.
The OES features 1500 VDC isolation and
overvoltage protection, as well as input
undervoltage lockout.
DESCRIPTION
General
Turn-On Time
Remote Shutdown
Switching Frequency, 3.3V Output
Switching Frequency, 5.0, 2.5, 2.1V Outputs
Isolation
Input - Output
Input - Case
Output - Case
Temperature Coefficient
Case Temperature
Operating Range
Storage Range
Thermal Shutdown Range
Vibration, 3 Axes, 5 Min Each
MTBF(Bellcore TR-NWT-000332)
Safety
Weight (Approx.)
10 ms
Positive Logic
400 kHz
300 kHz
1500 VDC
1050 VDC
500 VDC
±0.03%/°C
-40 To +100°C
-40 To +125°C
105 To 115°C
5 g, 10 - 55 Hz
2.5 X 106hrs
UL, cUL, TUV
1.4 oz
Ultra-Dense 40W
converter
Industry standard
package
100 °C baseplate
operation
Open-Frame packaging
5, 3.3, 2.5, and
2.1V Outputs
Remote Enable
Pin
1500V Isolation
Input Pi Filter
MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load, unless otherwise
stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Units are water-washable and fully compatible with commercial spray or
immersion post wave-solder washing equipment.
Notes
TECHNICAL SPECIFICATIONS
Voltage Range
48 VDC Nominal
Input Under Voltage Lockout
Input Undervoltage Hysteresis
Reflected Ripple
Input Reverse Voltage Protection
36 - 72 VDC
<34V
1V Nominal
50 mA Pk-Pk
Shunt Diode
Input
Output
Setpoint Accuracy
3.3/5.0 V Line Regulation V
in
Min. - V
in
Max., I
out
Rated
2.5/2.1 V Line Regulation V
in
Min. - V
in
Max., I
out
Rated
Load Regulation I
out
Min. - I
out
Max., V
in
Nom.
Minimum Output Current
±1%
0.2% V
out
0.4% V
out
0.5% V
out
10%, I
out
Rated
25% I
out
6% V
out
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
Voltage Trim Range
Short Circuit / Overcurrent Protection
Current Limit Threshold Range, % of I
out
Rated
OVP Trip Range
500
μ
s
±10%
Shutdown / Hiccup
110 - 140%
120 - 140% V
out
Nom.
V
in
Negative
Remote Shutdown Reference
Efficiency vs. Load (48V Input)