AC ELECTRICAL CHARACTERISTICS (Input tr = tf = 3.0 ns)
Symbol
Parameter
VCC
(V)
Test
Condition
TA = 25 5C
TA = +855C
TA = 555C
to +1255C
Unit
Min
Typ
Max
Min
Max
Min
Max
tPLH,
tPHL
Propagation Delay,
Input A to Output Y
2.32.7
RL = 1 MW,
CL = 15 pF
1.8
4.3
7.4
1.8
8.1
1.8
9.1
ns
3.03.6
RL = 1 MW,
CL = 15 pF
1.5
3.3
5.0
1.5
5.5
1.5
6.5
RL = 500 W,
CL = 50 pF
1.8
4.0
6.0
1.8
6.6
1.8
7.6
4.55.5
RL = 1 MW,
CL = 15 pF
1.0
2.7
4.1
1.0
4.5
1.0
5.5
RL = 500 W,
CL = 50 pF
1.2
3.2
4.9
1.2
5.4
1.2
6.4
CIN
Input Capacitance
5.5
VIN = 0 V or
VCC
2.5
pF
CPD
Power Dissipation
3.3
5.5
10 MHz
VIN = 0 V or
VCC
11
12.5
pF
6. CPD is defined as the value of the internal equivalent capacitance which is calculated from the dynamic operating current consumption without
load. Average operating current can be obtained by the equation ICC(OPR) = CPD VCC fin + ICC. CPD is used to determine the noload
dynamic power consumption: PD = CPD VCC2 fin + ICC VCC.
VCC
GND
50%
50% VCC
A or B
Y
tPHL
tPLH
Figure 3. Switching Waveforms
Figure 4. Test Circuit
PULSE
GENERATOR
RT
DUT
VCC
RL
CL
RT = ZOUT of pulse generator (typically 50 W)