NLX1G11
http://onsemi.com
4
AC ELECTRICAL CHARACTERISTICS (Input tr = tf = 2.5 nS)
Symbol
Parameter
VCC
(V)
Test
Condition
TA = 25 5C
TA = 555C to
+1255C
Unit
Min
Typ
Max
Min
Max
tPLH,
tPHL
Propagation Delay,
Input to Output
1.651.95
RL = 1 MW, CL = 15 pF
2.0
5.5
18.5
2.0
19
ns
2.32.7
RL = 1 MW, CL = 15 pF
0.8
3.0
11
0.8
11.5
3.03.6
RL = 1 MW, CL = 15 pF
0.5
2.6
7.5
0.5
8.0
RL = 500 W, CL = 50 pF
1.5
3.0
8.5
1.5
9.0
4.55.5
RL = 1 MW, CL = 15 pF
0.5
2.2
5.5
0.5
6.0
RL = 500 W, CL = 50 pF
0.8
2.4
7.0
0.8
7.5
CIN
Input Capacitance
5.5
VIN = 0 V or VCC
4.0
pF
CPD
Power Dissipation
3.3
5.5
10 MHz
VIN = 0 V or VCC
20
26
pF
7. CPD is defined as the value of the internal equivalent capacitance which is calculated from the dynamic operating current consumption without
load. Average operating current can be obtained by the equation ICC(OPR) = CPD VCC fin + ICC. CPD is used to determine the noload
dynamic power consumption: PD = CPD VCC2 fin + ICC VCC.